Power Supply Redundancy State Is Misleading When Only One Power Supply Is Installed; Hot-Swap Controller (Hsc) And Local Control Panel (Lcp) Updates May Take A Long Time; Console Redirection Baud Rate Setting Auto Changing To 19.2K With Serial Over Lan (Sol) Active - Intel BB5000XALR Specification

Specification update
Table of Contents

Advertisement

Monthly Specification Update
13.
Power supply redundancy state is misleading when only one power
supply is installed
Problem
If a single power supply is installed in a chassis that supports redundant power
supplies, the BMC indicates the power supply redundancy state as "redundant".
Implication
In a single power supply configuration, the redundancy sensor should be
ignored. Redundant chassis with fully redundant power supplies accurately
reflect the redundancy status.
Status
This erratum may be fixed in a future firmware revision.
Workaround
None.
14.
Hot-swap Controller (HSC) and Local Control Panel (LCP) updates may
take a long time
Problem
The Hot Swap Controller (HSC) and Intel
may take a long time. The time to complete each update could exceed 30
minutes.
Implication
Updating HSC and LCP may take a long time.
Status
This erratum may be fixed in a future firmware revision.
Workaround
None.
15.
Console Redirection Baud Rate Setting auto changing to 19.2K with
Serial Over LAN (SOL) active
Problem
If configuring a SOL connection, the only baud rate allowed is 19.2K. If any
other baud rate is selected, the system will always revert back to 19.2K after
the DC cycle.
Implication
Users will not be able to configure a SOL connection with a different baud rate
for their application.
Status
This erratum is fixed in BIOS release R0045 and later releases.
Workaround
None.