Security System Access Timeout Parameter Change - Baldor 15H SERIES 15H Installation & Operating Manual

15h series inverter control adjustable speed drive
Table of Contents

Advertisement

Section 1
General Information

Security System Access Timeout Parameter Change

Action
Apply Power
Keypad Display shows this
opening message.
If no faults and programmed for
LOCAL operation.
Press PROG key
Enter program mode.
Press Y or B key
Scroll to Level 2 Blocks.
Press ENTER key
Access Level 2 Blocks.
Press Y or B key
Scroll to the Security Control
block.
Press ENTER key
Access the Local Security block.
Press Y key
Scroll to the Access Timeout
parameter.
Press ENTER key
Attempt to access the Access
Timeout parameter.
Press B key
Use B key to change value.
Example: 8999.
Press ENTER key
Save Access Code parameter
Press SHIFT key.
Move cursor right on digit.
Press Y key 3 times
Change the 0 to 3.
Press ENTER key
Save value.
Press DISP key
Return to Display mode.
MN715
Description
Note: Please record your access code and store it in a safe place. If you cannot
gain entry into parameter values to change a protected parameter, please
contact Baldor. Be prepared to give the 5 digit code located on the lower right
side of the Keypad Display at the Enter Code prompt.
Display
Logo display for 5 seconds.
Display mode. Stop LED on.
V
represents blinking cursor.
Note: Ignore the 5 digit number to
the right (example: 23956).
Security code entered is correct.
All parameters may be changed.
Access Timeout can be any value
between 0 and 600 seconds.
Example: 30 seconds.
P: will change to L: after you
return to Display mode for longer
than the time specified in the
Access Time parameter.
Typical display mode.
Programming & Operation 4-11
Comments