Summary of Contents for ACME DVS-2500

  • Page 1 DigiVideo Spot 2500 DVS-2500 User Guide Please read these instructions carefully before use...
  • Page 2 DVS-2500...
  • Page 3: Table Of Contents

    DVS-2500 CONTENTS 1. Safety Instruction ....................... 2. Installation ..........................3. Technical Specification ....................4. Description ..........................4.1 Description of the fixture ..............11 4.2 Control Panel..................12 5. Lamp ............................6. How To Set The Unit ...................... 6.1 Display Status When Power On............14 6.2 Main Function ..................
  • Page 4: Safety Instruction

    DVS-2500 1. Safety Instruction Please read carefully the instruction manual which includes important information about the installation usage and maintenance. WARNING Please keep this User Manual for future consultation. If you sell the unit to another user, be sure that they also receive this instruction manual.
  • Page 5 DVS-2500 Avoid any inflammable liquids, water or metal objects entering the unit. Once it happens, cut off the mains power immediately. Do not operate in dirty or dusty environment; do clean the fixture regularly. Do not touch any wire during operation as there might be a hazard of electric shock.
  • Page 6: Installation

    DVS-2500 Product Items Digital Video Spot 2500 User manual 2 x Omega clamps 8GB memory SD card (packaged with user manual) 2. Installation 1. Bolt each clamp (1) to the Omega holder with screw and lock nut through the hole in the holder.
  • Page 7 DVS-2500 Fig.3 Attention: Always ensure that the structure to which you are attaching the unit is secure and is able to support a weight of 10 times of the unit’s weight. Also always use a safety cable that can hold 12 times of the weight of the unit when installing the fixture.
  • Page 8: Technical Specification

    DVS-2500 3. Technical Specification Power supply - AC 120V~240V 50/60Hz Power Consumption - 250W at 230V 50Hz - 260W at 120V 60Hz Fuse - T 5A Projector - Display technology: DLP by Texas Instruments - Lamp: Osram E20.8 180W Lamp...
  • Page 9 DVS-2500 - Supported video file types: AVI, MJPEG (From SD card: Max. video resolution is 720 x 480) (From computer: Max. video resolution is 800 x 600 ) Shutter - Blackout Cool - Fan cooled Protocols - DMX 512 - Date input/output: 3/5 Pin XLR socket Memory card - Memory card slot, hot swappable, max.
  • Page 10 DVS-2500 DMX Channels Mode Mode 1 Mode 2 Channel 54-CH 29-CH Pan Fine Pan Fine Tilt Tilt Tilt Fine Tilt Fine Pan/Tilt Speed Pan/Tilt Speed Pan/Tilt Macro Shutter Shutter Picture/Video Picture/Video Video Number Video Number Video Speed Video Speed Layer1 Picture Directory /Color...
  • Page 11 DVS-2500 Layer3 Center Offset Layer3 Center Rotation Layer3 X Zoom Layer3 Y Zoom Layer3 Zoom Macro Layer3 Rotation Picture Macro Picture Macro Center Offset Picture Macro Center Rotation Picture Macro X Zoom Picture Macro Y Zoom Picture Macro Zoom Macro...
  • Page 12: Description

    DVS-2500 4. Description 4.1 Description of the fixture 1. Head 2. Tilt lock 3. Pan lock 4. Front panel 5. Memory card slot 6. Arm 7. Handle 8. Back panel For transportation protection, please set the tilt lock/unlock (2) and the pan lock/unlock lever (3) in the lock position before any transportations.
  • Page 13: Control Panel

    DVS-2500 4.2 Control Panel Front View Rear View ○ 1 LCD Display: shows the various menus and the selected functions. ○ POWER Power on DMX input present ○ 3 Antenna W-DMX wireless receiver receive signal from a wide range. ○...
  • Page 14: Lamp

    DVS-2500 ○ 8 Power Cable: To connect to the mains AC outlet ○ 9 Fuse (T 5 A): Protect the unit from damage of over current. 5. Lamp Osram E20.8 180W Lamp Because of its high internal pressure, there might be a risk that the discharge lamp would explode during operation.
  • Page 15: How To Set The Unit

    DVS-2500 Change Lamp In case of replacement of the lamp or maintenance, do not open the fixture within 15 minutes until the unit cools down after switching off. WARNING 1. Turn off the power. 2. Unscrew the four screws (A), open the cover, and move it as the sketch shown.
  • Page 16: Main Function

    DVS-2500 Explanation of fig.5: Base 30°C Present temperature of base CPU is 30°C Present DMX start address Md.1 54Ch Present channel mode is mode 1 (54 channels mode) Warning signal blinking indicates resetting error, press Enter for more details. 6.2 Main Function Turn on the unit, press MENU button into menu mode, press UP and DOWN button until the required function is shown on the monitor.
  • Page 17 DVS-2500...
  • Page 18 DVS-2500 DMX Settings Enter menu mode, select DMX Settings, press ENTER button to confirm, press UP/DOWN button to select DMX Address, DMX Channel Mode, View DMX Value or WDMX Setting DMX Address—DMX512 address setting Select DMX Address, press ENTER button to confirm, the present address will blink on the display, press UP/DOWN button to adjust the address from 1 to 512, press ENTER button to store.
  • Page 19 DVS-2500 DMX Channel Mode—channel mode Select DMX Channel Mode, press ENTER button to confirm, present channel mode will blink on the display, press UP/DOWN button to select Mode1 (54 channels mode) or Mode 2 (29 channels mode), press ENTER button to store. Press MENU button back to the last menu or let the unit idle one minute to exit menu mode.
  • Page 20: Fixture Settings

    DVS-2500 Standby Settings Enter menu mode, select Stand Settings, press ENTER button to confirm, press UP/DOWN button to select Standby Mode or Eidt Standby Scene press ENTER button to store. Press MENU button back to the last menu or let the unit idle one minute to exit menu mode.
  • Page 21 DVS-2500 Image Auto Inverse Select Image Auto Inverse, press ENTER button to confirm, present mode will blink on the display, press UP/DOWN button to select No (normal) or Yes (Image auto inverse while the DMX value of tilt is over 128 ), press ENTER button to store. Press MENU button back to the last menu or let the unit idle one minute to exit menu mode.
  • Page 22 DVS-2500 On If DMX On— Lamp turns on when DMX signal is detected Select On If Dmx On, press ENTER button to confirm, present mode will blink on the display, press UP/DOWN button to select Yes (Lamp turns on when DMX signal is detected) or No (Lamp off when DMX signal is detected), press ENTER button to store.
  • Page 23 DVS-2500 Backlight Intensity Select Backlight Intensity, press ENTER button to confirm, present mode will blink on the display, press UP/DOWN button to adjust backlight intensity from 1 (darkest) to 10 (brightest), press ENTER button to store. Press MENU button back to the last menu or let the unit idle one minute to exit menu mode.
  • Page 24 DVS-2500 Lamp On Time Select Lamp On Time, press ENTER button to confirm, lamp on time will show on the display, press ENTER button to confirm, press UP/DOWN button to select Exit or Reset Time, press ENTER button to confirm. Press MENU button back to the last menu or exit menu mode let the unit idle one minute.
  • Page 25: Home Position Adjustment

    DVS-2500 All—Reset All Select All, press ENTER button to confirm, press UP/DOWN button to select Yes (the unit will run built-in program to reset all motors to their home positions) or No, press ENTER button to store. Press MENU button to exit.
  • Page 26: Memory Card

    DVS-2500 -128~127 Tilt -128~127 Offset Menu Shutter 0~255 Focus 0~255 Pan—pan home position adjust Enter offset mode, Select Pan, press ENTER button to confirm, the present position will blink on the display, use UP/DOWN button to offset the value from -128 to 127, press ENTER button to store.
  • Page 27 DVS-2500 Remove the memory card Important: Do not remove the memory card in the middle of an operation when the card is being accessed. Removing the card in the middle of an operation may damage the memory card as well as the device, and data stored on the card may be corrupted.
  • Page 28 DVS-2500 ① Image Folder - 32 picture folders, “Image000 ……Image031”. - At most it can contain 1024 (32 x 32) pictures. - Each folder can put at most 32 pictures in it. Pictures are changeable; please refer to the following diagram to name your own files if you want to change pictures:...
  • Page 29: Error Information

    DVS-2500 6.5. Error Information Lamp Startup Fail It appears when there is no lamp or some wires are damaged. Maintenance Fixture It appears when the maintenance remaining time becomes 0S, please maintain the unit after enter menu mode and reset the time.
  • Page 30: Channel Mode Setting

    DVS-2500 COMMON DMX - DMX + DMX INPUT DMX OUTPUT Not Used Not Used ATTENTION Termination reduces signal errors and avoids signal transmission problems and interference. It is always advisable to connect a DMX terminal (Resistance 120 ohm 1/4W between pin2 (DMX-) and pin3 (DMX+) of the last fixture).
  • Page 31: Address Setting

    DVS-2500 the last menu or let the unit idle one minute to exit menu mode. 7.3 Address Setting If you use a universal DMX controller to control the units, you have to set DMX address from 1 to 512 so that the units can receive DMX signal.
  • Page 32 DVS-2500 54 Channels (Mode 1):...
  • Page 33 DVS-2500 Notice: Put the DMX value of CH14 from 0~7 so that the function of CH11, CH12, and CH13 is enable. In the same time 15CH works as Preset Color. Layer 2 works as Shelter function of the background of layer one.
  • Page 34 DVS-2500...
  • Page 35 DVS-2500 ①: Layer1 ②: Layer2 ③: Layer3...
  • Page 36 DVS-2500...
  • Page 37 DVS-2500 29 Channels (Mode 2):...
  • Page 38 DVS-2500 ①: Layer1 ②: Layer2 ③: Layer3...
  • Page 39: Update Software

    DVS-2500 8. Update Software Download update file from our web site, follow the user manual of IU-01 to update the fixture via IU-01(not included). 9. Troubleshooting Following are a few common problems that may occur during operation. Here are some suggestions for easy troubleshooting: A.
  • Page 40 DVS-2500 3. If you have intermittent DMX signal problems, check the pins on connectors or on PCB of the unit or the previous one. 4. Try to use another DMX controller. 5. Check to see if the DMX cables run near or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit.
  • Page 41: Fixture Cleaning

    DVS-2500 F. If The tilt belt is broken 1. Turn off the mains power. 2. Loosen all the screws (A) and open the right arm cover (B). 3. Loosen the screws (C) that fix the bridge. 4. Change a new belt (D).
  • Page 43 EC Declaration of Conformity We declare that our products (lighting equipments) comply with the following specification and bears CE mark in accordance with the provision of the Electromagnetic Compatibility (EMC) Directive 2004/108/EC. EN55103-1:1996; EN55103-2:1996; EN61000-3-2:2006 EN61000-3-3:2008 & Harmonized Standard EN 60598-2-17: 1989 +A2: 1991 EN60598-1:2008+A11:2009 Part 1:General requirements and test Following the provisions of the low voltage directive 2006/95/EC...
  • Page 44 Innovation, Quality, Performance...