Make Gas Connection; Electronic Ignition System; Replace Oven Racks And Warming Drawer; Complete Installation - KitchenAid YKDRS807SS01 Installation Instructions Manual

30" (76.2 cm) freestanding and slide-in dual fuel ranges
Table of Contents

Advertisement

Available languages

Available languages

LP Gas Orifice Spud Chart for TripleTier ® Flame Burners
Burner Location
Burner Rating
Color
Size
Left front (external
11,800 Btu/h
Brown
1.00 mm
TripleTier _ burner)
Left front (internal
2,200 Btu/h
Orange
0.42 mm
TripleTier _'burner)
7. Replace burner plate, head and cap.
8. Place Natural gas orifice spuds in plastic parts bag for future
use and keep with literature package•
9. Reinstall the warming drawer• See the "Replace Oven Racks
and Warming Drawer" section for instructions.
10. Complete installation• See "Make Gas Connection"
and
"Electronic Ignition System" sections.
Checking for proper cooktop burner flames is very important.
The small inner cone should have a very distinct blue flame
1A" (0.6 cm) to V2" (1.3 cm) long. The outer cone is not as
distinct as the inner cone. LP gas flames have a slightly
yellow tip.
IMPORTANT: You may have to adjust the "LO" setting for
each cooktop burner.
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect anti-tip
bracket to rear range foot.
Reconnect the anti-tip bracket,
if the range is moved.
Failure to follow these instructions can result in death
or serious burns to children
and adults.
To Convert
Gas Pressure
Regulator
1. Turn manual shutoff valve to the "closed" position.
2. Unplug range or disconnect
power
................
B
A_ _
.........
..................
C
A. To range
B. Manual shutoff valve "closed" position
C. Gas supply fine
3. Remove warming drawer• See the "Remove Warming
Drawer" section for instructions•
Locate gas pressure
regulator at rear of warming drawer compartment.
4. Remove access cover from the gas pressure regulator•
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
Gas pressure
regulator
5. Remove the access cap by using a wrench, turning the
access cap counterclockwise.
6. Remove spring retainer from the cap by pushing against the
flat side of the spring retainer. Look at the spring retainer to
locate the "LP" or "NAT" position.
7. Turn over the spring retainer so the "NAT" is showing on the
bottom.
8. Snap the spring retainer back into the cap.
9. Reinstall the cap onto the regulator.
A
J
E
D
C
A. Access cap
D. Spring retainer
B. Gasket
NAT position
C. Gas pressure regulator
E. Spring retainer
LP position
To Convert Standard Surface
Burners
1. Remove burner cap.
2. Using a T20 TORX _ screwdriver, remove the burner base.
3. Apply masking tape to the end of a 7 mm nut driver to help
hold the gas orifice spud in the nut driver while changing it.
Press nut driver down onto the gas orifice spud and remove
by turning it counterclockwise
and lifting out, set gas orifice
spud aside.
A. Igniter electrode
B. Gas tube opening
C. Burner cap
D. Burner base
21