2. Using a pipe wrench to tighten, connect the gas supply to the
range.
B
F:
A
C
D
A. Y_"or _A" gas pipe
B. Manual gas shutoff valve
C. Nipple
D. Union
E. 90 ° elbow
F. Black iron pipe
G. Union
H. Nipple
I. 90 ° elbow (must have
V2" male pipe thread)
J. Gas pressure regulator
Typical flexible
connection
1. Apply pipe-joint compound
made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see C
and G in the following illustration).
2. Attach one adapter to the gas pressure regulator and the
other adapter to the gas shutoff valve. Tighten both adapters.
3. Use a 15/16" c ombination
wrench and channel lock pliers to
attach the flexible connector to the adapters. Check that
connector is not kinked,
H
E
F
A
c
D
G
A. ½" or 3/4" gas pipe
B. Manual gas shutoff valve
C. Use pipe-joint
compound.
D. Adapter
E. Flexible connector
E Adapter (must have Y_" male
pipe thread)
G. Use pipe-joint
compound.
H. Gas pressure regulator
Complete
Connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
4.
5=
If burner caps are not properly positioned, surface burners
will not light.
C
.....
A. Burner base
B. Burner cap
C. Burner grate
Place burner grates over burners and caps as shown in the
following illustration, When properly installed the grates
should not overlap the console.
Freestanding
Ranges
A
J
" "_.......
A. Opening in grate for wok insert to be
located over left front burner.
Slide-In Ranges
A. Large flange with rounded corner must be at
rear corner of the cooktop
Plug in range or reconnect power. "Clock-Enter Time" should
appear in the display, For further information, please refer to
the user instructions
located in the Use and Care Guide.
A. Closed valve
B. Open valve
2. Test all connections
by brushing on an approved
noncorrosive leak-detection
solution. If bubbles appear, a
leak is indicated. Correct any leak found.
3. Remove cooktop burner caps and grates from parts
package. Align notches in burner caps with pins in burner
base. Burner caps should be level when properly positioned.
Initial lighting and gas flame adjustments
Cooktop burners use electronic igniters in place of standing
pilots, When the cooktop control knob is turned to the "LITE"
position, the system creates a spark to light the burner. This
sparking continues, as long as the control knob is turned to
"LITE,"
Check Operation
of Cooktop
Burners
Standard Surface
Burners
Push in and turn each control knob to the "LITE" position,
The flame should light within 4 seconds. The first time a burner is
lit it may take longer that 4 seconds to light because of air in the
gas line.
17