Make Gas Connection; Ce Cece Secre Renscerereeseereeneees - KitchenAid KDRS505XSS00 Installation Instructions Manual

30" (76.2 cm) double oven dual fuel ranges
Hide thumbs Also See for KDRS505XSS00:
Table of Contents

Advertisement

Available languages

Available languages

2.
Attach terminal lugs (located in the package containing
literature) to line 1 (black), bare (green) ground, and line 2 (red)
wires. Loosen (do not remove) the setscrew on the front of the
terminal lug and insert exposed wire end through bottom of
terminal lugs. Securely tighten setscrew to
XX Ibs-in. torque. See Bare Wire Torque Specifications chart.
A
A. Terminal lug
B. Setscrew
C. Line 1 (black) wire
D. Bare (green) ground wire
E. Line 2 (red) wire
Bare Wire Torque Specifications
Attaching terminal lugs to the terminal block - 20 Ibs-in. (2.3 N-m)
Wire Awg
Torque
Make Gas Connection
AWARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
8 gauge copper
25 lbs-in. (2.8 N-m)
6 gauge aluminum
35 Ibs-in. (4.0 N-m)
3.
Use %" nut driver to connect the bare (green) ground terminal
lug to the center terminal block post with one of the 10-32 hex
nuts.
A. 10-32 hex nut
B. Line 1 (black)
C. Ground-link screw
D. Bare (green) ground wire
E. Line 2 (red)
F. Terminal lug
4.
Connect line 1 (black) and line 2 (red) terminal lugs to the outer
terminal block posts with 10-32 hex nuts.
5.
Securely tighten hex nuts.
6.
Replace terminal block access cover.
16
Typical flexible connection
1.
Apply pipe-joint compound made for use with LP gas to the
smaller thread ends of the flexible connector adapters (see B
and G in the following illustration).
2.
Attach one adapter to the gas pressure regulator and the other
adapter to the gas shutoff valve. Tighten both adapters.
3.
Use ate" combination wrench and an adjustable wrench to
attach the flexible connector to the adapters. Check that
connector is not kinked.
E. Manual gas shutoff valve
F. ¥2" or %4" gas pipe
G. Use pipe-joint compound.
H. Adapter
A. Gas pressure regulator
B. Use pipe-joint compound.
C. Adapter (must have 2" male
pipe thread)
D. Flexible connector

Advertisement

Table of Contents
loading

Table of Contents