Electrical
Shock Hazard
Electrically
ground
range.
Failure to do so can result in death, fire, or
electrical
shock.
If codes permit and a separate ground wire is used, it is
recommended
that a qualified electrical installer determine that
the ground path is adequate and wire gauge are in accordance
with local codes.
Be sure that the electrical connection
and wire size are adequate
and in conformance
with CSA Standard C22.1, Canadian
Electrical Code, Part 1 - latest edition, and all local codes and
ordinances.
A copy of the above code standards can be obtained from:
Canadian Standards Association
178 Rexdale Blvd.
Toronto, ON M9W 1R3 CANADA.
Check with a qualified electrical installer if you are not sure
the range is properly grounded.
When a 4-wire, single phase 120/240 volt, 60 Hz., AC only
electrical supply is available, a 50-amp maximum circuit
protection is required (or, if specified on the model/serial
rating plate, when a 4-wire, single phase 120/208 volt 60 Hz.,
AC only electrical supply is available, a 40-amp maximum
circuit protection is required), fused on both sides of the line.
A time-delay fuse or circuit breaker is recommended.
This range is equipped with a CSA International Certified
Power Cord intended to be plugged into a standard 14-50R
wall receptacle. Be sure the wall receptacle is within reach of
range's final location.
Do not use an extension cord.
Explosion
Hazard
Use a new CSA International
approved
gas supply
line.
Install a shut-off
valve.
Securely
tighten
all gas connections.
If connected
to LP, have a qualified
person
make
sure
gas
pressure
does
not exceed
14" (36 cm) water
column,
Examples of a qualified
person
include:
licensed
heating personnel,
authorized
gas company
personnel,
and
authorized
service
personnel.
Failure to do so can result in death, explosion,
or fire.
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes
and ordinances.
In the absence of local codes, installation must
conform with American National Standard, National Fuel Gas
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest
edition.
IMPORTANT:
Leak testing of the range must be conducted
according to the manufacturers
instructions.
Type of Gas
Natural gas:
This range is design-certified
by CSA International for use with
Natural gas or, after proper conversion, for use with LP gas.
This range is factory set for use with Natural gas. See "Gas
Conversions"
section. The model/serial
rating plate located
on the right side oven door trim has information on the types
of gas that can be used. If the types of gas listed do not
include the type of gas available, check with the local gas
supplier.
LP gas conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the appliance from the gas
specified on the model/serial rating plate for use with a different
gas without consulting the serving gas supplier. See "Gas
Conversions"
section.
Gas Supply Line
Provide a gas supply line of 3A" (1.9 cm) rigid pipe to the
range location. A smaller size pipe on longer runs may result
in insufficient gas supply. Pipe-joint compounds
that resist
the action of LP gas must be used. Do not use TEFLON _'t
tape. With LP gas, piping or tubing size can be r/2" (1.3 cm)
minimum. Usually, LP gas suppliers determine the size and
materials used in the system.