3-24 RAID Array 3000 Controller Shelf Hardware User's Guide

Controller Shelf Status LED's

15. Connect the UPS serial control cable (17-04729-01) from the UPS
connector controller shelf host 0 I/O module to the like connector on the
UPS.
16. Install jumper connector 12-49700-01 to the controller shelf UPS
connector on the host 1 I/O module.
CAUTION: To prevent possible damage to the equipment, the input voltage level
of the UPS must be set to your specific line voltage before proceeding. Refer to
the UPS manual and set the input level to your AC power source.
17. After the UPS has been set to the correct input voltage level, set the low-
battery warning option to five minutes (refer to UPS manual for
instructions).
18. This completes the controller and device expansion shelf cabling
procedure. Dress and tie-wrap related cable groups, and then refer to the
Getting Started RAID Array 3000 Installation Guide and Command
Console V2.2 for the RAID Array 3000 (Pedestal and Rack Mount
Models) User's Guide for information describing how to setup and
configure your subsystem.
The controller shelf is equipped with two front-panel LEDs that monitor the
following error conditions (see Figure 3-14):
A shelf blower that is not operating
An over-temperature condition
A DC power problem
External fault conditions
Controller faults
When the shelf is operating properly, the green power LED is On and the
amber shelf fault LED is Off. If a DC power problem develops, the power
LED turns Off indicating a malfunction.