Check the appliance is electrically safe and gas sound when you have nished.
Fig.7-8
Stability chain
Fig.7-9
Stability bracket
3 mm min
ArtNo.070-0014 - Stability bracket - Wall fitting
Fig.7-10
Outer stability
bracket
Wall
Typical wall mounting
Fig.7-11
40
80
140
'A'
330
ArtNo.062-0002 - 90SC - Prof+ - Gas connection
All dimensions in millimetres
Cooker
Typical oor mounting
Cooker
3 mm min
Floor
All dimensions in millimetres
INSTALLATION

Fitting the Stability Bracket or Chain

Unless otherwise stated, a cooker using a exible gas
connector must be secured with a suitable stability device.
Suitable stability devices are shown in Fig.7-8, Fig.7-9 and
Fig.7-10.
If you are using a stability chain (Fig.7-8) then the chain
should be kept as short as is practicable and xed rmly to
the rear of the cooker.
If you are using a stability bracket (Fig.7-9 and Fig.7-10), then
adjust the bracket to give the smallest practicable clearance
between the bracket and the engagement slot in the rear of
the cooker.
Fit the bracket so that it engages as far as possible over the
chassis of the cooker.

Gas Connection

Must be in accordance with the relevant standards. A hose
is not supplied with the cooker. Hoses may be purchased at
most builders' merchants.
Floor
The gas supply needs to terminate with a down-facing
bayonet.
The hose should be tted so that both inlet and outlet
connections are vertical so that the hose hangs downwards
in a 'U' shape. Ideally the hose supply connection should be
within the shaded area 'A' (Fig.7-11).
The connector is located just below the hotplate level at the
rear of the cooker.
For Natural Gas the exible hose must be in accordance with
BS 669.
For LP Gas it should be capable of 50 mbar pressure, 70 °C
temperature rise and carry a red stripe, band or label.
If in doubt contact your supplier. Screw connect the threaded
end of the hose into the gas inlet.
After completing the gas connection, check the cooker is gas
sound with a pressure test.

Pressure Testing

The gas pressure can be measured at the pressure test point on
the gas connection block.
Connect the pressure gauge. Turn on and light one of the
hotplate burners.
See the data badge for test pressures.
Turn o the burners and remove the pressure gauge.
Check the appliance is gas sound.
n
n
Check operation of all the burners.
n
n
22