Electrical Connection; Final Checks - Falcon 900S Dual Fuel User's Manual & Installation Instructions

Hide thumbs Also See for 900S Dual Fuel:
Table of Contents

Advertisement

Check the appliance is electrically safe and gas sound when you have nished.

Electrical Connection

This appliance must be installed by a quali ed electrician
to comply with the relevant Institute of Electrical Engineers
(I.E.E.) regulations, and also the local electricity supply
company requirements.
WARNING: THIS APPLIANCE MUST BE EARTHED.
n
n
Current Operated Earth Leakage Breakers
The combined use of your cooker and other domestic
appliances may cause nuisance tripping, so we
recommend that the cooker is protected on an individual
RCD (Residual Current Device) or RCBO (Residual Current
Breaker with Overload).
IF IN DOUBT, PLEASE CONSULT A SUITABLY QUALIFIED
ELECTRICIAN.
Note: The cooker must be connected to the correct electrical
supply as stated on the voltage label on the cooker, through
a suitable cooker control unit incorporating a double-pole
switch, having a contact separation of at least 3 mm in all poles.
The total electrical load of the appliance is approximately
3.6 kW. The cable size used should be suitable for this load
and comply with all local requirements.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect
the mains cable to the correct terminals for your electrical
supply type (Fig.7-12 and Fig.7-13). Check that the links are
correctly tted and that the terminal screws are tight.
Secure the mains cable using the cable clamp.
These appliances are of type X with regard to protection
against overheating of the surrounding surfaces.

Final Checks

Hotplate Check
Check each burner in turn (refer to the 'Hotplate Burners'
section at the front of the instructions).
Check each burner in turn.
Oven Check
Turn on the oven and check that it starts to heat up. Check
that the oven lights are working. Turn o the oven.
Note: The oven light bulb is not included in the guarantee.
INSTALLATION
L
N
10 mm² max
ArtNo.130-0010 Electrical connections single-phase
230 V ac 50 Hz
L1
N
L3
L2
6 mm² max
3N ac
230/400 V 50 Hz
23
Fig.7-12
Fig.7-13
10 mm² max