Electrical Connection - Falcon 1000 DF User's Manual & Installation And Servicing Instructions

1000 dual fuel
Table of Contents

Advertisement

Available languages

Available languages

English
a) Position and level the appliance.
b) Draw a pencil line along the front edge of the
base of the cooker and along the right hand edge.
c) Remove the range.
d) Mark off 570mm from the RH side of the unit to
indicate the centre line for the bracket.
e) Mark off 415mm to locate the front edge of the
lower bracket. Fix bracket to fl oor.
f)
Measure the height from fl oor level to the bottom
of the opening in the cooker back. Add 3mm to
this dimension and assemble the stability bracket
to this height (i.e. from fl oor level to underside of
top member)
Gas Connection
The Gas supply needs to terminate with a down facing
bayonet. The rear cover boxes limit the position of the
supply point.
view from the rear
Because the height of the cooker can be adjusted and
each connection is different it is diffi cult to give precise
dimensions. Ideally the house supply bayonet should
be in the shaded area shown in the diagram. The hose
should be fi tted so that both inlet and outlet connections
are vertical so that the hose hangs downwards in a 'U'
shape. A 3ft (915mm) hose will need to be connected
from the side
For Natural Gas the fl exible hose must be in accordance
with B.S.669.
For LP Gas it should be capable of 50mbar pressure,
70C temperature rise and carry a red stripe, band or
label.
If in doubt contact, your supplier.
Screw connect the threaded end of the hose into the gas
inlet in the underside of the connector block on the back
of the cooker.
After completing the gas connection, check the cooker
is gas sound with a pressure test. When checking
for gas leaks do not use washing up liquid - this can
corrode. Use a product specifi cally manufactured for leak
detection.
Pressure testing
The gas pressure can be measured at the pressure test
point on the gas connection block.
Connect the pressure gauge. Turn on and light one of
the hotplate burners.
For Natural Gas the pressure should be 20mbar.
For Propane the pressure should be 37mbar.

Electrical Connection

This appliance must be installed by a qualifi ed
electrician to comply with the relevant regulations and
also the local electricity supply company requirements.
WARNING: THIS APPLIANCE MUST BE EARTHED
Note
The cooker must be connected to the correct electrical
supply as stated on the voltage label on the cooker,
through a suitable cooker control unit incorporating
a double pole switch having a contact separation of
at least 3mm in all poles. This cooker must not be
connected to an ordinary domestic power point.
The total electrical load of the appliance is approximately
8.8kW. The cable size used should be suitable for this
load and comply with all local requirements.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel.
Connect the mains cable to the correct terminals for your
electrical supply type.