Minimum gas flow to burner is governed by size of fixed by-pass screw aperture as follows.
Model
Open top
SECTION 2 – ASSEMBLY and COMMISSIONING
2.1
Unpack appliance and place it in position using feet adjusters to level appliance.
Units with castors should be fitted with accessories supplied according to separate instructions
provided.
Open oven door, pull out shelves and base panel. Check burner spark igniter arrangements are
correctly located and secured. Ensure ALL packing, etc. is removed from oven. Replace all parts
in reverse sequence.
Check open top and remove tape, packing, etc. from hob area and ensure that all burners and pan
supports are secured in position. The open top burner heads fit loosely upon aluminium bases of lift-off
construction.
2.1.1 Fryplate Accessory
If fryplate (Figure 1) is supplied, refer to user instructions for details. Important note: this should be
operated on a low flame setting only.
2.1.2 Flue Accessory
A tall flue is available as an accessory that may be substituted for standard type supplied with unit.
Details of alteration process are indicated in Figures 2 through 6.
Remove hob as detailed in Sections 3.2.2 and 3.2.3. Undo and remove fixings at locations shown in
Figure 2. Remove fixings at rear detailed in Figure 3.
Install replacement flue as detailed in Figure 4 and secure using existing fixings at hob and rear at
positions indicated in Figures 5 and 6.
Important
Note: It is not possible to fit a splashplate / plateshelf to a model fitted with a tall flue.
2.2

CONNECTION TO GAS SUPPLY

2.3

CONNECTION TO ELECTRICAL SUPPLY

A 13A socket is required in close proximity to accommodate plug supplied.
Natural gas
Propane gas
marked
marked
76
51
ASSEMBLY
Note - The following paragraphs should be read as applicable to the unit being
assembled.
Connect appliance to gas supply and ensure that governor supplied is fitted on
NATURAL gas installations. Test for gas tightness.
The integral gas supply downstream of gas valve may be checked by applying leak
detection spray with burner lit. Inlet connection terminates at upper rear RH side in
Rp¾ (¾" BSP female).