Setting Frame Rate - Teledyne DALSA HS-40-04k40-xx-R User Manual

High sensitivity line scan ccd camera
Table of Contents

Advertisement

42
Figure 24: Mode 7 Camera Timing
Internal Sync set
with
Command
ssf

Setting Frame Rate

Purpose:
Syntax:
Syntax Elem ents:
N otes:
Related Com m and s:
Exam ple:
03-032-20013-03
Frame Period
Exposure Time
Readout
Sets the cam era's fram e rate in H z. Cam era m ust be operating in
exposure m od e 7.
ssf i
i
Set the fram e rate to a value from :
TDI
H S-40-4k40: 3499.87-36563.1
H S-80-4k40: 3499.87-68610
H S-80-8k40: 3499.56-34305.3
H S-80-8k80: 3499.87-68610.6
H S-82-4k80: 3499.87-111111
Area
H S-40-4k40: 1-3783.58
H S-80-4k40: 1-6169
H S-80-8k40: 1-3084.52
H S-80-8k80: 1-6169.03
H S-82-4k80: 1-9017.13
Value round ed up/ d ow n as required . The m axim um
line/ fram e rate is affected by horizontal and vertical binning
factors, throughput setting, Cam era Link m od e, and num ber of
CCD integration stages.
If you enter an invalid fram e rate frequency the value, the
cam era clip s the fram e rate to be w ithin the current operating
range and a w arning m essage is returned .
If you enter a fram e rate frequency outsid e of the range
d isplayed on the help screen, an error m essage is returned and
the fram e rate rem ains unchanged .
The cam era d oes not autom atically change the fram e rate after
you change binning or stage selection values. You m ay have to
ad just your fram e rate to avoid ignored syncs.
To return the cam era's fram e rate, use the com m ad
ssf.
sem
ssf 10000
Piranha HS-xx RoHS User Manual