When entering com m and s, rem em ber that:
The follow ing param eter conventions are u sed in the m anu al:
Example: to return the current camera settings

Setting Baud Rate

Purpose:
Syntax:
Syntax Elem ents:
N otes:
Exam ple:

Camera Help Screen

For qu ick help, the cam era can retu rn all available com m and s and param eters throu gh the
serial interface.
There are tw o d ifferent help screens available. One lists all of the available com m and s to
configu re cam era operation. The other help screen lists all of the com m and s available for
retrieving cam era param eters (these are called ―get‖ com m and s).
To view the help screen listing all of the camera configuration commands, use the command:
Syntax:
03-032-20013-03
A carriage retu rn <CR> end s each com m and .
A space or m u ltiple space characters separate param eters. Tabs or com m as are invalid
param eter separators.
Upper and low ercase characters are accepted
The backspace key is su pported
The cam era w ill answ er each com m and w ith either <CR><LF> ―OK >" or
<CR><LF>"Error xx: Error Message >" or <CR><LF>―Warning xx: Warning Message
>‖. The ">" is u sed exclu sively as the last character sent by the cam era.
i
= integer valu e
f
= real nu m ber
m
= m em ber of a set
s
= string
t
= tap id
x
= pixel colu m n nu m ber
y
= pixel row nu m ber
gcp
<CR>
Sets the speed in bps of the cam era serial com m unication port.
sbr m
m
Baud rate. Available baud rates are: 9600 (Default), 19200,
57600, and 115200.
Pow er-on rate is alw ays 9600 baud .
The
the pow er-on baud rate and w ill reboot using the last used
baud rate.
sbr 57600
h
rc
(reset cam era) com m and w ill not reset the cam era to