Led Status Indicator; Power Connector - Teledyne DALSA HS-40-04k40-xx-R User Manual

High sensitivity line scan ccd camera
Table of Contents

Advertisement

Piranha HS-xx RoHS User Manual

2.2.1 LED Status Indicator

The cam era is equ ipped w ith a red / green LED u sed to d isplay the operational statu s of
the cam era. The table below su m m arizes the operating states of the cam era and the
correspond ing LED states.
When m ore than one cond ition is active, the LED ind icates the cond ition w ith the highest
priority. Error and w arning states are accom panied by correspond ing m essages fu rther
d escribing the cu rrent cam era statu s.
Table 3: Diagnostic LED
Priority
1
2
3
4

2.2.2 Power Connector

Figure 10: Hirose 6-pin Circular Male—Power Connector
Hirose 6-pin Circular Male
The cam era requ ires a single voltage inpu t (+12 to +15VDC). The cam era m eets all
perform ance specifications u sing stand ard sw itching pow er su pplies, althou gh w ell -
regu lated linear su pplies provid e optim u m perform ance.
!
WARNING: When setting up the camera's power supplies follow these guidelines:
Note: Camera performance specifications are not guaranteed if your power supply does not
meet these requirements.
Teledyne DALSA
Color of Status LED
Flashing Red
Solid Red
Flashing Green
Solid Green
6
1
5
2
4
3
Mating Part: HIROSE
HR10A-7P-6S
Apply the appropriate voltages
Protect the cam era w ith a
Do not u se the shield on a m u lti-cond u ctor cable for grou nd .
Keep lead s as short as possible to red u ce voltage d rop.
linear
Use high-qu ality
su pplies to m inim ize noise.
Use an isolated type pow er su pply to prevent LVDS com m on m od e range violation.
Meaning
Fatal Error. Cam era tem perature is too high and
cam era therm al shutd ow n has occurred or a pow er
on failure has been d etected .
Warning. Loss of functionality.
Cam era initialization or executing a long com m and
(e.g., flat field correction com m and s ccp or ccf)
Cam era is operational and functioning correctly .
Table 4: Hirose Pin Description
Pin
Description
1
Min +12 to Max +15VDC
2
Min +12 to Max +15VDC
3
Min +12 to Max +15VDC
fast-blow fuse
betw een pow er su pply and cam era.
19
Pin
Description
4
GN D
5
GN D
6
GN D
03-032-20013-03