Operation
Remote Programming of Output Voltage and Current Limit
Programming
The output voltage can be programmed using either a 0-5Vdc or 0-10Vdc external
voltage source. To program the output voltage with a 0-5Vdc source, set switch
With External
SW1-3 open (default factory setting) and remove the jumpers connecting pins 8 to 9
Voltage
and 20 to 21 on connector J3. Connect the external source between pins 9 (positive)
Sources
and 12 (return). Varying the external voltage from 0-5V will cause the output to vary
from 0-100% of rated output.
Figure 3.7 SW1/J3 Configuration for 0-5V Programming of the Output Voltage
For programming with a 0-10Vdc source, close switch SW1-3 and replace the 0-5V
source with a 0-10V source.
Figure 3.8 SW1/J3 Configuration for 0-10V Programming of the Output Voltage
48
(J3 sense line, OVP and current control jumpers shown set for local operation)
(J3 sense line, OVP and current control jumpers shown set for local operation)
Operating Manual for XKW 1kW Series Power Supply