Danish Interpretation Systems
Technical specifications
Digital Section
Sound quality ......... 20 bit audio @ 32 kHz sampling frequency
Analogue Section
Output signal type...............ground lifting transformer balanced
Nominal output level: ...........................0 dBm at nominal input
Max. Output level:..........................................................15 dBm
Frequency response .................................................... 50-15kHz
Signal to noise ratio: .................................................. >85 dBA
Total harmonic distortion: .............................................< 0.1%
General
Power requirement...................................................24-48 V DC
Power consumption ............................................. 5W maximum
Power supplied from
...................................CU 6005 / CU 6010 / EX 6010 / PS 6000
Temperature to guarantee specified performance
..............................5 Deg C. to 40 Deg C. (35 to 80% humidity)
Storage temperature
.......................... -20 Deg C. to 60 Deg C. (10 to 80% humidity)
Weight .............................................................................. 4,5 kg
Dimensions (W x H x D).......... 425 (483) x 87 x 317 (357) mm
dimensions in bracket are including 19" brackets
Accessories supplied .............................................. User manual
Connectors
DCS-LAN network............................................... 2 pieces RJ45
Analogue outputs connectors ........... 8 - XLR3 male connectors
Remote Control commands in/out
By using SW 6000 the user can control the AO 6008 through
the CU 6005/6010. A number of control messages are used for
this communication.
The CU 6005/6010 can read the following info from the AO
6008:
* ............................................................................... Error status
* ............................................ Channel number for each channel
* .............................................. Volume setting for each channel
* ........................................................................... Serial number
* .......................................................................Software version
* ......................................................................Hardware version
The CU 6005/6010 can control the following settings:
* .................................................... Volume steps for all channel
* .........Channel number for each output channel and headphone
* ......................Volume setting for each channel and headphone
* ................................................................. Error counter (reset)
The settings can be controlled from the SW 6000 or using the
AO 6008 User Interface (with exception of setting of volume
steps.
The CU 6005/6010 continuously monitors the status of the AO
6008 to ensure that updated status of the unit is always present
on the CU 6005/6010.
Specifications are subject to change without notice.
Manual 01 18 04440
User Manual