Danish Interpretation Systems DCS 600 User Manual

Danish Interpretation Systems DCS 600 User Manual

Digital conference system audio output unit with firmware 5.3.5 or later

Advertisement

DCS 6000
User Manual
Digital Conference System
AO 6008 Audio Output Unit
with firmware 5.3.5 or later
Danish Interpretation Systems
DIS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DCS 600 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Danish Interpretation Systems DCS 600

  • Page 1 DCS 6000 User Manual Digital Conference System AO 6008 Audio Output Unit with firmware 5.3.5 or later Danish Interpretation Systems...
  • Page 2 Danish Interpretation Systems User Manual Copyright © 2007 DIS AO6008 REV M.DOC 16-01-2007 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher...
  • Page 3: Table Of Contents

    Danish Interpretation Systems User Manual List of Contents General description ..........7 List of Contents............. 3 Features............7 Important .............. 4 User controls, indications & connections ..8 Compliancy............4 Setup ..............9 Installation precautions ........4 Normal operation ...........12 Cleaning ............. 4 System Setup............13 Repacking ............
  • Page 4: Important

    Danish Interpretation Systems User Manual Important exposed to direct sunlight, excessive dust or Compliancy humidity, mechanical vibration or shock. To avoid moisture condensations do not install the The equipment has been tested and found to comply unit where the temperature may rise rapidly. with the limits of the following standards for digital devices: Cleaning...
  • Page 5: Description Of The Dcs 6000 System

    Danish Interpretation Systems User Manual Description of the DCS 6000 system RS232/RS422 connection on CU 6005/6010 for Features external operation of the system of a PC or control system such as AMX or Crestron The DCS 6000 system has the following main features: The SW 6000 is an optional software package, which expands the functionality of the DCS 6000...
  • Page 6: System Components

    Danish Interpretation Systems User Manual Conference equipment and channel System components selectors The CU 6005/6010 Central Unit supports all CS 6032FV/H Channel Selector (flush mounted) available units in the DCS 6000 series: CM/DM 6010P Conference Unit (portable) DM 6060P Conference Unit (portable) with Central equipment etc.
  • Page 7: Operating Instructions

    Danish Interpretation Systems User Manual Operating instructions A number of AO 6008 can be combined to AO 6008 Audio Output Unit decode more channels. Up to 20 pieces AO 6008 can be connected and configured in one General description system to decode more channels. User control of the AO 6008 by using the The AO 6008 Audio Output Unit for the DCS 6000 buttons and display on the front or by sending...
  • Page 8: User Controls, Indications & Connections

    Danish Interpretation Systems User Manual User controls, indications & connections Front plate layout The front plate layout of the AO 6008 Audio Output Unit consists of a large illuminated LCD display and 8 buttons for setting up/controlling the unit: A: 12ALB E: 13DAN B: 14ENG 1FIN...
  • Page 9: Setup

    Danish Interpretation Systems User Manual DCS-LAN connector Symbols Two RJ45 sockets are located at the back of the unit The following symbols are used on the LCD for connecting to the previous unit like the CU display: 6005/6010 Central Unit or any other unit with a DCS LAN connector and to the next unit like an IS ‘-‘...
  • Page 10 Danish Interpretation Systems User Manual Channel setup menu The volume level for a specific output is changed in the same way as the language setting by pressing If the “Channel setup” entry is chosen the Channel one of the four SELECT buttons. The changes are menu is shown: applied instantly to the audio when the up/down -Out A: 12Polish...
  • Page 11 Danish Interpretation Systems User Manual shows the number of errors encountered on the The settings are then transferred to another unit by incoming and outgoing busses since last error reset. executing the “Paste from clipboard” command on If the number of errors on the outgoing bus exceeds that unit.
  • Page 12: Normal Operation

    Danish Interpretation Systems User Manual carrying floor audio (because there is no The lock status is being saved in the CU 6010 and interpretation taking place on the channel). The retransmitted to the unit after power up. attenuation level can be adjusted between -20 and 0 dB.
  • Page 13: System Setup

    Danish Interpretation Systems User Manual System Setup General guidelines Connect the AO 6008 to the various units using Cat Maximum cable length in one chain when 5 FTP or STP cables. Please observe the following using repeaters is 650 m. guide lines: If the last unit in one chain is a CS 6032 Channel Maximum cable length in one chain is 200...
  • Page 14: Typical Schematics

    Danish Interpretation Systems User Manual Typical schematics Connect the AO 6008 to the DCS 6000 network for recording the interpreted channels or to IT6008 using Cat 5 cables. The Analogue Audio output Infrared Transmitter(s) transmitting connectors are connected to either Tape recorders interpreted channels wireless.
  • Page 15: Using Ao 6008 With Dt 60Xx Digital Ir-Transmitter

    Danish Interpretation Systems User Manual Using AO 6008 with DT 60xx Digital IR-Transmitter When using the AO 6008 with the DT 60xx factory preset, but can as earlier mentioned be Infrared Transmitter, the audio output level on the changed using SW 6000. The DT-60XX input level AO 6008 has to be set to match the sensitivity on settings should be set to –6dB.
  • Page 16: Appendix

    Danish Interpretation Systems User Manual Appendix Technical appendix Cabling The phase of the pairs must be correct and the wiring spec. as stated in CAT5 (EIA 568-B) have to CAT5 be followed. The DCS 6000 system uses CAT5, CAT5e or Note: CAT6 cables can normally only be CAT6 FTP or STP cables with screened RJ45 terminated in sockets (female) and not in cable...
  • Page 17: Technical Specifications

    Danish Interpretation Systems User Manual Technical specifications Digital Section Remote Control commands in/out Sound quality ..20 bit audio @ 32 kHz sampling frequency By using SW 6000 the user can control the AO 6008 through the CU 6005/6010. A number of control messages are used for Analogue Section this communication.