Table 7-1. Configuration Requirements For Circuit Recovery - ADTRAN MX2800 User Manual

M13 multiplexer
Hide thumbs Also See for MX2800:
Table of Contents

Advertisement

Chapter 7. Circuit and Network Redundancy
Selection Path
Config > Network Interface > XCV Threshold
Config > Network Interface > Network Protection
Config > Network Interface > Max. Switch Threshold
Config > Network Interface > Min. Switching Period
Config > T1/E1 Interface > T1/E1 Circuit Protection
Config > T1/E1 Interface > XCV Threshold
The XCV Threshold settings are based on the error rates considered ac-
ceptable on the DS3 or DS1 before switching.
7-4

Table 7-1. Configuration Requirements for Circuit Recovery

MX2800 User Manual
Recommended Setting
1E-3 (see the following note)
Disabled
3
10 seconds
Enable all or select the T1/
E1s that redundant switching
should occur on.
1E-3 (see the following note)
61200290L1-1