ADTRAN MX2800 User Manual page 59

M13 multiplexer
Hide thumbs Also See for MX2800:
Table of Contents

Advertisement

DS2 Alarm Traps
Trap
OOF
AIS
RAI
T1/E1 Alarm Traps
Trap
Local T1/E1 Alarms
LOS
CAIS (carrier
side AIS)
LAIS (loop side
AIS)
XCV
T1/E1 Failure
In/Out Test
Far-End Alarms (only available in C-Bit Parity mode)
Multiple DS1
LOS
Single DS1
LOS
DS1 Eqpt Fail
SA
DS1 Eqpt Fail
NSA
61200290L1-1
If enabled, the unit issues a trap when...
the DS2 detects a framing loss from the net-
work.
the DS2 is receiving an AIS (blue) alarm condi-
tion from the network. AIS alarms occur when
the unit is receiving unframed all ones.
the DS2 is receiving an RAI (yellow) alarm from
the network. This alarm is a signal sent back to-
ward the source of a failed transmit circuit. The
X-bits (X1 and X2) are set to zero.
If enabled, the unit issues a trap when...
the unit has lost the Rx signal on a T1/E1.
the T1 is receiving all ones from the DS3 side
of the network.
the T1 is receiving all ones from the DSX-1 in-
terface.
the unit is receiving excessive code violations
across a T1/E1, exceeding the configured
threshold (see XCV Threshold on page 3-12).
a T1/E1 has failed.
a T1/E1 is going in and out of test.
the far-end equipment has lost multiple T1/E1
lines.
the far-end equipment has lost a single T1/E1.
a service-affecting equipment failure is being
reported by the far-end.
a non-service-affecting equipment failure is be-
ing reported by the far-end.
MX2800 User Manual
Chapter 3. Configuration
3-23