Replacing The Dc Output Fuse - Xantrex TC1012 Owner's Manual

Truecharge2 series
Hide thumbs Also See for TC1012:
Table of Contents

Advertisement

Replacing the DC Output Fuse

WARNING: Shock hazard
The following information is for qualified installers or service
personnel only.
To replace the DC Output Fuse:
1. Disconnect all AC and DC sources to the charger and
2. Locate the fuse cover on the charger's top panel (see
3. Loosen the screw on the fuse cover using a Phillips
4. Pull out the blown fuse(s) gently, using the provided fuse
5. Install a brand new fuse(s) with same type and rating as
CAUTION
For continued protection, replace only with Littelfuse
equivalent) with ratings as shown below.
975-0401-01-01
wait five minutes for internal voltage and energy
levels to reduce to safe levels.
Figure 1-1, "Truecharge™ 2 Battery Charger" on
page 1–4).
screwdriver.
NOTE: The screw will not separate from the cover.
puller.
NOTE: The fuse puller is located on the inside of the
cover.
the old one.
Amperage
Model
TC1012
15 A (blue)
TC1512
25 A (natural)
TC2012
30 A (green)
TC3012
40 A (amber)
Replacing the DC Output Fuse
Voltage
32 Vdc
32 Vdc
32 Vdc
32 Vdc
®
type 257 (or
3–11