Remote Software; Setup Remote Connection; Configuring The Dvr; Configuring A Remote Pc - OpenEye OE2-E12016 User Manual

E-series digital video recorder
Hide thumbs Also See for OE2-E12016:
Table of Contents

Advertisement

REMOTE SOFTWARE

SETUP REMOTE CONNECTION

The administrator and up to five additional users can access the DVR remotely using software installed on a computer running
Windows XP or Windows Vista.

CONFIGURING THE DVR

1.
Press SETUP on the front of the DVR or remote control to log in.
2.
Select NETWORK > CLIENT SETUP (See the Client Setup section of this manual for more details).
3.
Change port settings or write down current port settings.
4.
Select SAVE to save current settings.
5.
Go to SYSTEM > USER MANAGEMENT > CLIENT to add remote users.
Note
Only users defined in SYSTEM > USER MANAGEMENT > CLIENT will be able to access the system remotely.
6.
Select SAVE to save current settings.
7.
Select NETWORK SETUP (see the NETWORK SETUP section of this manual for more details).
8.
Enable or clear DHCP depending on the network (Ask the network administrator for assistance).
9.
If DHCP is cleared – define the IP address and additional network information.
10. If DHCP is enabled – write down the IP address supplied by the DVR system.
Note
If the DVR does not display the IP Address after setting DHCP to ON, Select Save to change the network and
open Network Setup again.
11. Select SAVE to save current settings.

CONFIGURING A REMOTE PC

1.
Install the Remote Software on a PC using the software disc provided with your DVR.
2.
Open the Remote Software. The Local Setup window will open automatically.
3.
Click New.
4.
Select OpenEye E-120 as the Site Type.
5.
Enter a name for the system in the Site Name Field.
6.
Enter the IP address of the DVR – found in Network Setup on the E120 system.
7.
Enter the Port number found in Client Setup on the E120 system (default is 2000).
8.
Click OK.
9.
Enter the user name and password of an authorized remote user as defined in Network > Client Setup > User on the
E120 system.
Note
User Name and Password are both case sensitive.
10. Click Connect.
27717AN
51