A P P E N D I X
118
®
Intel
Express 530T Switch Users Guide
Optional module default settings
•
FX Module Port Speed:
100Mbps
•
FX Module Flow Control: IEEE
802.3x
•
SX/LX Module Port Speed:
1000Mbps
•
SX Module Flow Control: IEEE
802.3x
Troubleshooting/FAQs
I booted the switch, and the status LED stays orange, is
something wrong?
By default, the switch is in BootP mode, and the LED stays orange
while the switch waits for an IP address from the BootP server. In
order to proceed with the boot, either bypass the BootP phase (refer
to the Quick Start guide for instructions), or manually assign an IP
address.
If the switch doesn't receive an IP address from the BootP server
within ten minutes, it will continue the boot process as normal.
How can I set the speed or duplex on individual ports?
Normally the switch handles all connections automatically but if you
need to force speed or duplex, (for example, to accommodate older
devices that don't support autonegotiation) use the Local Manage-
ment or Web Device View.
When I set the 530T to autonegotiate with flow control
enabled and try to connect to another device, there is no
link. Why?
Check the settings of the other device and disable flow control. If you
want to use flow control on the port, force the speed, duplex, and flow
control settings so that they match.
•
FX Module Port Duplex: Full
Duplex
•
FX Module Priority: Use Frame
Tag
•
SX/LX Module Port Duplex:
Full-Duplex
•
SX Module Priority: Use Frame
Tag