Inputs Tab - Honeywell NetAXS User Manual

Access control unit
Table of Contents

Advertisement

Configuring via the Web Server
Configuring the Doors
Table 2-6: Configuration > Doors > Output Tab Field Descriptions (continued)
Setting
First Card Rule

2.4.3 Inputs Tab

Three inputs are associated with each of the four doors on a NetAXS™ panel:
• Status – Provides the following door status information:
• Egress – Allows the door to open or close normally without generating an alarm.
• Tamper – Reports abnormal handling of the reader device or wiring.
2-30
www.honeywell.com
Description
Requires a valid card read before the time zone (period in
which doors are unlocked) can take effect. For example, the
principal of a school would normally open the school with a
valid card read, and the time zone becomes active at its
normal time. When the school is cancelled due to a storm,
the principal stays home, the doors are not opened, and the
time zone does not become active at its normal time. Note
that both Snow Day and First Card Rule cannot be enabled
at the same time.
– Normal – Reports that the door's state is currently in its normal state, either Normally Open
or Normally Closed.
– Alarm – Reports that the door's state is currently in its abnormal state: if the door is
configured as Normally Open, its abnormal state is to be closed; if the door is configured as
Normally Closed, its abnormal state is to be open.
– Shorted (supervised input only) – Reports that the electrical circuit supporting the door and
its devices has been short-circuited
– Cut (supervised input only) – Reports that the electrical circuit supporting the door has been
cut or disconnected.
.

Hide quick links: