NetAXS™ Standalone Operation
NetAXS Panel Defaults

4.3 Reader Tamper Inputs

The card readers have a Tamper signal wired to the NetAXS™ panel. This is a
two-state input configured as a Normally Closed contact.
The following are the default Reader Tamper Input to Panel Input associations:
Tamper LED
Tamper 1
Tamper 2
Tamper 3
Tamper 4

4.4 Door Egress Inputs

The panel has a Request-To-Exit (egress) input for each door. The default condition is
a two-state input configured as Normally Closed contact. When the egress input is
active, the associated output relay will be active.
The following are the default egress input associations:
Egress input
1
2
3
4
76
www.honeywell.com
Reports as...
Input 9
Input 10
Input 11
Input 12
Controls relay...
Panel input
1
SP1
2
SP3
3
SP5
4
SP7
Reports as...
Input 1
Input 3
Input 5
Input 7