Power Sub-System - Intel SR1500 - AXXMINIDIMM DDR-2 RAID Controller Cache Memory Manual

Server chassis/server system
Hide thumbs Also See for SR1500 - AXXMINIDIMM DDR-2 RAID Controller Cache Memory:
Table of Contents

Advertisement

Intel® Server System SR1550AL
1.7

Power Sub-system

The system can support up to two 650 Watt power supply modules providing support for either a
non-redundant 1+0 or redundant 1+1 power configuration. In a 1+1 redundant configuration,
each power supply module is hot-swappable should one fail.
The power sub-system has several integrated management features including:
Status LED on each power module
Over temperature protection circuitry
Over voltage protection circuitry
Over current and 240VA protection circuitry
Power dropout and brownout recovery
With the addition of Server Management Software, the power subsystem is capable of
supporting several system management features including:
Remote Power On/Off
Status Alerting
Module and PDB FRU Information Reporting
PSMI Capabilities:
Thermal management
Relative temperature sensor for monitoring hot spot in power supply
Fan speed sensor
System control of power supply fan
Power supply fan control override indicator
Power monitoring
Output currents (12V)
AC Input current
AC input voltage
Diagnostics
Shutdown events; general failure, over current, over temperature, and loss of
AC input
Warning events; low input voltage, high current, high temperature, slowing
fan
Status
Fan control override mode
Signals; PWOK, PSON
Input voltage range indicator
SMBAlert#
Revision – 1.3
A
Slimline Optical Drive Bay
B
Mini Control Panel Bay (Filler Panel Shown)
C
Standard Control Panel
2.5" Hard Drive Bays (Up to Eight Possible with Mini Control
D
Panel)
Intel order number D31982-006
Product Overview
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sr1550Sr1550al

Table of Contents