Oce 9600 User Manual page 201

Copier/printer
Table of Contents

Advertisement

HPGL-2
Pen priori-
Pen parameters can be defined in two ways:
ty
- In the plot data file
- In the Remote Configuration File (RCF) or Océ Job Ticket
(OJT)
If pen priority is set to 'Language', the pen parameters defined in
the plot data file will be used. If pen priority is set to 'Setup', the
pen parameters defined in the configuration file or the job ticket
received with the plot will be used.
PS no clip
If 'PS no clip' is set to 'On' and the plot defines a Page Size (PS)
value of WxH (Width and Height), the PS is not taken into ac-
count. In that case, the plot may be bigger or smaller than the PS.
Emulation
You can use the 'Emulation type' option to determine the type of
type
printer you want to emulate: HP650C or HP750C. The default
emulation type is HP650C, which is compatible with older ma-
chines. Differences occur in the default pen palette and the de-
fault number of pens. If HP750C is selected, the default palette
is a gray level palette and compatible with HP750C.
Line at-
If the 'HP default' value is set, the Line Attributes instruction is
tributes
fully emulated. All types of lines ends/joins allowed by the Line
attributes specifications will be therefore printed according to
these specifications. For backward compatibility reasons, the in-
terpretation of this instruction can be disabled ('Océ Round val-
ue). In that case, the lines of the plot will be processed as rounded
and without join.
Pen width
To enable or disable the pen width scaling.
scaling
If enabled: scaling an image will scale the pen width correspond-
ingly.
System administrator settings
201

Advertisement

Table of Contents
loading

Table of Contents