IBM xSeries 200 Hardware Maintenance Manual page 10

Xseries 200 type 8479 and xseries 200vl type 8481
Hide thumbs Also See for xSeries 200:
Table of Contents

Advertisement

1. IS THE SYSTEM PART OF A CLUSTER?
YES. Schedule maintenance with the customer. Shut down all systems related to
the cluster. Run storage test.
NO. Go to step 2.
2. IF THE SYSTEM IS NOT PART OF A CLUSTER:
3. DID YOU RECEIVE BOTH OF THE CORRECT RESPONSES?
NO. Find the failure symptom in "Symptom-to-FRU index" on page 89.
YES. Run the Diagnostic Programs. If necessary, refer to "Diagnostic programs and
error messages" on page 10.
If you receive an error, go to "Symptom-to-FRU index" on page 89.
If the diagnostics completed successfully and you still suspect a problem, see
"Undetermined problems" on page 97.
2
xSeries 200 Type 8479 and xSeries 200VL Type 8481: Hardware Maintenance Manual
v Power-off the computer and all external devices.
v Check all cables and power cords.
v Set all display controls to the middle position.
v Power-on all external devices.
v Power-on the computer.
v Record any POST error messages displayed on the screen. If an error is
displayed, look up the first error in the "POST error messages" on page 95.
v Check the System Error Log. If an error was recorded by the system, see
"Symptom-to-FRU index" on page 89.
v Start the Diagnostic Programs. See "Diagnostic programs and error
messages" on page 10.
v Check for the following responses:
a. One beep.
b. Readable instructions or the Main Menu.