Adjusting Spreader Bar Width

NOTE: For this procedure, refer to FIGURE 4.18.
NOTE: The spreader bar can be adjusted from 16 to 20 inches or from 20 to 24 inches.
NOTE: This procedure only applies to systems without Contoura backs that omit upholstery.
1. Remove spreader bar. Refer to Removing/Installing the Spreader Bar on page 58.
2. Remove the two screws, four coved spacers and two locknuts securing the two 
handles to the tube.
3. Align the handle mounting holes with the desired tube mounting holes.
4. Secure the two handles to the tube using the two screws, four coved spacers and two 
locknuts. Torque to 75 in‐lbs ± 20%.
Screws
Coved Spacer
Handle
16 to 20-inch Tube
Part No. 1125038
Coved Spacer
Tube
Coved Spacer
Handle Mounting
Hole
DETAIL "A" - TUBE MOUNTING HOLES
20 Inches
19 Inches
18 Inches
17 Inches
16 Inches
FIGURE 4.18 Adjusting Spreader Bar Width
Coved
Spacer
Locknuts
20 to 24-inch Tube
59
SECTION 4—SEAT
Handle
Handle
Mounting Hole
24 Inches
23 Inches
22 Inches
21 Inches
20 Inches
®