Hp Procurve Switch Problems; Hp Procurve Switch Diagnostics - HP Cluster Platform Introduction v2010 Introduction Manual

Hp cluster platform core components overview
Hide thumbs Also See for Cluster Platform Introduction v2010:
Table of Contents

Advertisement

Item
Description
6
Port LED
View
7
T/M
* The blinking behavior is an on/off cycle once every 1.6 seconds, approximately.**The flashing behavior is an on/off
cycle once every 0.5 seconds, approximately.
None of the rear panels of the HP ProCurve switches have any LEDs.

5.3 HP Procurve Switch Problems

The LED patterns on the HP ProCurve switch can indicate problem conditions.
some of the possibilities.
Table 5-1 HP ProCurve Switch Diagnostics
Power
Fault
a
Off with
power cord
plugged in.
On
Prolonged on
On
Blinking
On
Blinking
On
Blinking
On
Off
On
Off
a
This LED is not important for the diagnosis.
b
The blinking behavior is an on/off cycle once every 1.6 seconds, approximately.
State
Meaning
4 green LEDs
Link = Indicates that the port LEDs are displaying link information. If the
port LED is on, the port is enabled and receiving a link indication from
the connected device. If the port LED is off, the port has no active network
cable connected, or is not receiving link beat or sufficient light. Otherwise,
the port may have been disabled through the switch console, the Web
browser interface, or HP TopTools. If the port LED is blinking*
simultaneously with the Fault LED, the corresponding port has failed its
self-test.
Act = Indicates that the port LEDs are displaying network activity
information.
FDx = Indicates that the port LEDs are lit for ports that are in full-duplex
mode.
Spd = Indicates that the port LEDs are displaying the connection speed at
which each port is operating. If the port LED is off, the port is operating
at 10 Mb/s. If the port LED is flashing**, the port is operating at 100 Mb/s,
and if the port LED is on continuously, the port is operating at 1000 Mb/s.
Green — ports 49
T = Indicates the 10/100/1000Base-T RJ-45 port is enabled.
and 50 only
M = Indicates the mini-GBIC port is enabled.
Self- Test
Fan Status
a
a
a
Prolonged on
b
b
a
Blinking
b
Off
Blinking
b
b
a
Blinking
a
Off
a
Off
Port LED
Problem
a
The interconnect is not plugged
into an active AC power source,
or the switch's power supply may
have failed.
a
An interconnect hardware failure
has occurred. All the LEDs will
stay on indefinitely.
a
The interconnect has experienced
a software failure during self-test.
a
One or both of the cooling fans
may have failed.
b
Blinking
The network port for which the
LED is blinking has experienced
a self-test or initialization failure.
Off with cable
The network connection is not
connected.
working properly.
On, but the port
The port may be improperly
is not
configured, or the port may be in
communicating.
a blocking state.
5.3 HP Procurve Switch Problems
Table 5-1
describes
75

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Cluster Platform Introduction v2010 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

Cluster platform

Table of Contents