HP 6125G Configuration Manual page 46

Network management and monitoring configuration guide
Hide thumbs Also See for 6125G:
Table of Contents

Advertisement

Sysname (host name or host IP address)
If the system information that is sent to a log host is in the UNICOM format, and the info-center
loghost source command is configured, or vpn-instance vpn-instance-name is provided in the
info-center loghost command, the field is displayed as the IP address of the device that generates
the system information.
If the system information is sent to other destinations, or is sent to a log host in the HP format, the
field is displayed as the system name of the device that generates the system information. You can
use the sysname command to modify the system name. For more information, see Fundamentals
Command Reference.
%% (vendor ID)
This field indicates that the information was generated by an HP device.
It exists only in logs sent to a log host in the HP format.
vv
This field identifies the version of the log, and has a value of 10.
It exists only in logs sent to the log host.
module
This field specifies the source module name. You can execute the info-center source ? command in system
view to view the module list.
level (severity)
System information is divided into eight severity levels, from 0 to 7. See
about severity levels. You cannot change the system information levels generated by modules. However,
you can use the info-center source command to control the output of system information based on severity
levels.
digest
This field briefly describes the content of the system information. It contains a string of up to 32 characters.
For system information destined to the log host:
If the character string ends with (l), the information is log information.
If the character string ends with (t), the information is trap information.
If the character string ends with (d), the information is debugging information.
For system information destined to other destinations:
If the time stamp starts with a percent sign (%), the information is log information.
If the time stamp starts with a pound sign (#), the information is trap information.
If the time stamp starts with an asterisk (*), the information is debugging information.
serial number
This field indicates the serial number of the device that generates the system information. It is displayed
only when the system information is sent to a log host in the format of UNICOM.
source
This optional field identifies the source of the information. It is displayed only when the system information
is sent to a log host in HP format. It can take one of the following values:
IRF member ID
39
Table 1
for more information

Advertisement

Table of Contents
loading

This manual is also suitable for:

6125 blade switch series

Table of Contents