PRI (priority)
The priority is calculated by using this formula: facility*8+level, where:
facility is the facility name, ranging from local0 to local7 (16 to 23 in decimal integers) and defaults
to local7. It can be configured with info-center loghost. It is used to identify different log sources on
the log host, and to query and filter logs from specific log sources.
level ranges from 0 to 7. See
Note that the priority field is available only for information that is sent to the log host.
timestamp
Times tamp records the time when the system information was generated. The time stamp of the system
information sent to the log host has a precision of seconds, and that to all the other destinations has a
precision of milliseconds. The time stamp format of the system information sent to the log host is
configured with the info-center timestamp loghost command, and that of the system information sent to
the other destinations is configured with the info-center timestamp command.
Table 5 Description on the time stamp parameters
Time stamp
parameter
boot
date
iso
none
no-year-date
Table 1
Description
Time since system startup, in the format of
xxxxxx.yyyyyy, where xxxxxx represents the
higher 32 bits, and yyyyyy represents the
lower 32 bits.
System information that is sent to all
destinations except the log host supports this
parameter.
Current date and time of the system, in the
format of Mmm dd hh:mm:ss:sss yyyy.
All system information supports this
parameter.
Time stamp format stipulated in ISO 8601
All system information supports this
parameter.
No time stamp is included.
All system information supports this
parameter.
Current date and time of the system, with year
information excluded.
Only the system information that is sent to the
log host supports this parameter.
for more information.
Example
%0.109391473 Sysname
FTPD/5/FTPD_LOGIN: User ftp
(192.168.1.23) has logged in
successfully.
0.109391473 is a time stamp in the boot
format.
%May 30 05:36:29:579 2011 Sysname
FTPD/5/FTPD_LOGIN: User ftp
(192.168.1.23) has logged in
successfully.
May 30 05:36:29:579 2011 is a time
stamp in the date format.
<189>2011-05-30T06:42:44
Sysname %%10FTPD/5/FTPD_LOGIN(l):
User ftp (192.168.1.23) has logged in
successfully.
2011-05-30T06:42:44 is a time stamp in
the iso format.
% Sysname FTPD/5/FTPD_LOGIN: User
ftp (192.168.1.23) has logged in
successfully.
No time stamp is included.
<189>May 30 06:44:22
Sysname %%10FTPD/5/FTPD_LOGIN(l):
User ftp (192.168.1.23) has logged in
successfully.
May 30 06:44:22 is a time stamp in the
no-year-date format.
38