Configuring The Nqa Server; Enabling The Nqa Client - HP 6125G Configuration Manual

Network management and monitoring configuration guide
Hide thumbs Also See for 6125G:
Table of Contents

Advertisement

Task
Configuring the collaboration function
Configuring threshold monitoring
Configuring the NQA statistics collection function
Configuring the history records saving function
Configuring optional parameters for an NQA test group
Configuring a schedule for an NQA test group

Configuring the NQA server

To perform TCP, UDP echo, UDP jitter, or voice tests, configure the NQA server on the peer device. The
NQA server responds to the probe packets sent from the NQA client by listening to the specified
destination address and port number.
To configure the NQA server:
Step
1.
Enter system view.
2.
Enable the NQA server.
3.
Configure the listening
service.
4.
Configure the ToS value in
the packets sent by the TCP
or UDP listening service.

Enabling the NQA client

Configurations on the NQA client take effect only when the NQA client is enabled.
To enable the NQA client:
Configuring FTP tests
Configuring HTTP tests
Configuring UDP jitter tests
Configuring SNMP tests
Configuring TCP tests
Configuring UDP echo tests
Configuring voice tests
Configuring DLSw tests
Command
system-view
nqa server enable
nqa server { tcp-connect |
udp-echo } ip-address
port-number
nqa server { tcp-connect |
udp-echo } tos tos
100
Remarks
Optional.
Optional.
Optional.
Optional.
Optional.
Required.
Remarks
N/A
Disabled by default.
The destination IP address and port
number must be the same as those
configured on the NQA client. A
listening service must be unique on the
NQA server.
Optional.
By default, the ToS value is 0.