Yamaha SRCD User Manual page 98

Profibus network board
Hide thumbs Also See for SRCD:
Table of Contents

Advertisement

CHAPTER2 PROFIBUS Unit
(26) Subtraction of specified value
from counter arrangement variable C ................................. Code 011A
The specified value is subtracted from the counter arrangement variable C speci-
fied with the arrangement element specification command (code 0117).
QWn+22
IWm+22
(Details)
Addition value:
A value of 1 to 65535 can be specified.
(Example)
Transmission example 1:
10 is subtracted from the counter arrangement variable C.
Response example 1:
It is normally ended.
Command option
QWn+20
QWn+18
Command response
IWm+20
IWm+18
QWn+22
QWn+20
QWn+18
0000
0000
0000
IWm+22
IWm+20
IWm+18
0000
0000
0000
92
QWn+16
QWn+14
IWm+16
IWm+14
QWn+16
QWn+14
QWn+12
0000
0000
000A
IWm+16
IWm+14
IWm+12
0000
0000
0000
QWn+12
Subtraction value
IWm+12
QWn+10
QWn+8
0000
011A
IWm+10
IWm+8
0000
0200

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents