Yamaha SRCD User Manual page 87

Profibus network board
Hide thumbs Also See for SRCD:
Table of Contents

Advertisement

(15) General-purpose output or
memory output status change .............................................. Code 010F
ON/OFF control of the general-purpose output or memory output is performed.
QWn+22
IWm+22
(Details)
DO/MO/SOnumber:
One is specified among the general-purpose output 0 to 12 (13
points)*, serial general-purpose output 200 to 231 (32 points) or
memory output 100 to 131 (32 points).
Output status: 1 means ON, and 0 means OFF.
(Example)
Transmission example 1:
The serial general-purpose output 203 is turned ON.
Response example 1:
It is normally ended.
* 0 to 4 (5 points) for the SRCP/SRCD series controllers
Command option
QWn+20
QWn+18
Command response
IWm+20
IWm+18
QWn+22
QWn+20
QWn+18
0000
0000
0000
IWm+22
IWm+20
IWm+18
0000
0000
0000
81
CHAPTER2 PROFIBUS Unit
QWn+16
QWn+14
Output status
IWm+16
IWm+14
QWn+16
QWn+14
QWn+12
0000
0001
00CB
IWm+16
IWm+14
IWm+12
0000
0000
0000
QWn+12
DO/MO/SO
number
IWm+12
QWn+10
QWn+8
0000
010F
IWm+10
IWm+8
0000
0200

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents