Advertisement

Conettix Communications Receiver/
Gateway
9

Power

9.1

Power Supply Modules

9.2

Main Power

D6600 Power Input
AC Nominal Operating Range
AC maximum Operating Range
Power Cord
Replaceable Fuse
D6100IPv6 Power Input
AC Nominal Operating Range
9.3

Standby Power

Notice!
i
Refer to the appropriate Installation Supplement included with your product for the specifics
of your particular installation.
During a loss of AC power, the receiver automatically switches to standby power. External
batteries or an uninterruptible power supply (UPS) provides standby power. As long as there
is adequate standby power, the receiver's operation is not interrupted, even if the power loss
occurs during signal processing. When power supervision is enabled and a loss of AC power
occurs, the primary reporting devices (such as printers and computers) show AC FAIL and the
D6600/D6100IPv6 power indicator starts blinking. When AC power restores, the power
indicator stops blinking and reporting devices show AC RESTORE.
9.4

Connecting External Batteries

Notice!
Do not connect an external battery charger to the D6600/D610IPv6 or its battery. There is a
i
risk of explosion if the battery is replaced by an incorrect type. Dispose of used batteries ac-
cording to the instructions.
Use the terminal on the rear panel to connect an external DC power source. During AC power
outages, the external DC source supplies power to the receiver. Use a 12 VDC, 7 to 18 Ah
lead-acid battery for external backup power.
Battery Voltage
Above 11.5 V
Bosch Security Systems, Inc.
120 V or 230 V
100 VAC to 120 VAC, 220 VAC to 240 VAC, 50–60 Hz
2.5 A maximum
IEC 60320 C13 type
2.5A F250V Fast blow 5x20mm
18VAC (Refer to the specific Installation Supplement
supplied with your product for your application for
supplied transformer specifics)
Display during AC power
outage
Battery OK
Installation and Operation Guide
Power | en
Display if no battery when
AC power is restored
2012.11 | 08 | 4998122704
27