Table of Contents

Advertisement

Connect S2 | Solar Frame | User Guide
1 | 39
BOSCH CONNECTED INDUSTRY
CONNECT S2 GATEWAY
SOLAR FRAME
User Guide
Connected Products and Services
Nexeed Track and Trace
Version 1.19
© Robert Bosch Manufacturing Solutions GmbH
Bosch Connected Industry

Advertisement

Table of Contents
loading

Summary of Contents for Bosch ConnectS2

  • Page 1 Connect S2 | Solar Frame | User Guide 1 | 39 BOSCH CONNECTED INDUSTRY CONNECT S2 GATEWAY SOLAR FRAME User Guide Connected Products and Services Nexeed Track and Trace Version 1.19 © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 2 Connect S2 | Solar Frame | User Guide 2 | 39 © Robert Bosch Manufacturing Solutions GmbH, 2019. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
  • Page 3: Table Of Contents

    Mounting with Solar Frame, glued on backside ......................22 Mounting with Solar Frame, screwed ......................... 23 Operation and maintenance ............................ 24 Support ..................................24 Technical data ................................25 Gateway Connect S2 ..............................25 © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 4 Safety instructions for mounting with magnets ......................34 Safety instructions for handling the mounting magnets ....................35 Safety instructions for mounting with Solar Frame ..................... 36 Third-Party Licenses and Components ........................37 © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 5: Hints For This Document

    Indicates precautionary measures or/and a hazard that may result in minor or moderate injury.  These instructions should always be observed. Meaning of Info and Tip INFO General information and/or instructions.  These instructions must be observed. Practical hints. © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 6: Introduction

    2 Introduction Bosch Nexeed Track and Trace is a complete solution for tracking, locating and monitoring large and small objects. The Nexeed Gateway Connect S2 is a tracking device for mobile use on larger objects and vehicles and for stationary use by mounting inside and outside buildings.
  • Page 7: General Information

    8, provides an overview of all options. The Connect S2 supports a variety of functions and configuration options. Bosch delivers pre-set Connect S2 to the customer to make commissioning as easy and quick as possible. When ordering, the customer selects the desired...
  • Page 8: Sets, Accessories, Mounting Material And Ordering Information

    Screws M8 x 15 mm Spring washers Power supply adapter Device: Connect S2 solo Single device for use with the Solar Frame or as a replacement. Order number: 3843.AW2.504 Quantity Product Picture Gateway Connect S2 © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 9: Set: Solar Frame

    The set is used to fix the Solar Frame on a carrier (gluing) or through a carrier with a thickness of 4 mm up to 13 mm (screwing through). Order number: 3843.AY0.452 Quantity Product Picture Gluing studs M5 x 25 mm © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 10: Accessories: Adhesive Set At-8040

    The power supply is required for use in countries with US plug and 110 V mains voltage, only for use in the USA and Canada. Order number: 3843.AY0.456 Quantity Product Picture AC power supply 110 V (US connector) Indoor use only. © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 11: Spare Part: Power Supply Europe

    Washer DIN 522 stainless steel A2 blank 6.4 x 35 x 1.5 mm Flange nuts self-locking DIN 6926 A2 M5 Plugs Contact Nexeed Track and Trace for further information on sales and support at the following e-mail address: sales.tnt@de.bosch.com Indoor use only. © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 12: Functions And Configurations

    Data upload to server every 10 min Over 50 different configurations are available. The smallest interval is 3 minutes. Please contact our Nexeed Track and Trace support at the following e-mail address: support.tnt@de.bosch.com © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 13: Battery Stretch Function

    Battery-Stretch 3: at battery level of 5%... 0%: Sensor scan and position determination: every 3 min x 2 = every 6 min Data upload to server: every 3 min x 8 = every 24 min © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 14: Activation And Coupling Of The Connect S2

    Use the mobile apps provided by Bosch Connected Industry to link (couple) the Connect Gateway to your asset. The apps can read the unique ID, which is encoded in a QR code on the gateway, and transmit this information to the Bosch server along with your asset ID.
  • Page 15: Mounting

    The radio antennas required for the functions of the Connect S2 are located under the device surface (below the data matrix code). For optimum function, these antennas must not be covered by metal objects. © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 16: Mounting With Magnets

     DO NOT attach the gateway to the outside of moving objects such as trucks, trailers, cars or other vehicles using the magnets. When handling the mounting magnets, please also observe the corresponding safety instructions, see Safety notes page 34. chapter © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 17: Mounting With M8 Screws

    Use the spring washers supplied to secure the screws. Screw the screws from below into the threads provided on the gateway housing. See the following picture: Mounting parameters: Screw tightening torque 5 Nm to 7 Nm Screw-in depth in the Gateways housing min. 10 mm to max. 14 mm © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 18: Mounting Instructions For Solar Frame

    Replace a damaged Solar Frame.  It is recommended that you first plug the Solar Frame connector into the gateway and tighten it before inserting the gateway into the Solar Frame. © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 19: Usage Of Adhesive At-8040

    Press the fixing element firmly onto the substrate until the adhesive swells out to the sides. Depending on the selected adhesive, the fastener can be used within 15 to 45 minutes. © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 20: Mounting With Solar Frame, Glued

    G60/30 Gloss sanded standard Cover sheet – outside Schmitz Cargobull Cover sheet – inside (PVC) Kögel Cover sheet – outside Krone Cover sheet – outside Cover sheet – outside Kiesling Cover sheet – inside © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 21 8. Gluing the Solar Frame 9. Wait until the adhesive has cured before loading 10. Check that all four mounting points hold the Solar Frame Exploded view Rear view Side view © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 22: Mounting With Solar Frame, Glued On Backside

    9. Mounting according to exploded view 10. Check that all four mounting points hold the Solar Frame 11. Close the screw holes with the supplied plugs Exploded view Rear view Side view © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 23: Mounting With Solar Frame, Screwed

    8. Screw the Solar Frame hand-tight with the four flange nuts supplied 9. Check that all four mounting points hold the Solar Frame 10. Close the screw holes with the supplied plugs Exploded view Rear view Side view © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 24: Operation And Maintenance

    The Connect Gateway has no shutdown switch. The device can only be switched off remotely by support. INFO Connect Gateways must be switched off during flight! 9 Support For further questions please contact Nexeed Track and Trace support at the following e-mail address: support.tnt@de.bosch.com © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 25: Technical Data

    Based on ambient temperature +25°C and good mobile radio conditions. Depending on configuration, quantity of sensors and operating conditions. The external voltage source used to operate the device must meet the requirements for LPS ("limited power source") according to IEC/EN 60950-1, section 2.5 or IEC/EN 62368-1, Annex © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 26: Ac Power Supply

    -20 °C to +60 °C Working humidity 20% to 90% rH (non-condensing) IP protection class IP22 indoor use only Observe the data on the nameplate or the installation instructions and the Note manufacturer's data sheet. © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 27: Solar Frame

    -20 °C to +75 °C Charging temperature 0 °C to 45 °C (integrated protection circuit) Storage temperature +10 °C to +30 °C Storage time 6 months Humidity 20% rH to 100% rH (non-condensing) © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 28: Handling And Transport

    Protection of battery by housing of device and potting of battery. Packaging No special packaging requirements. Lithium battery mark UN 3481, if more than 2 devices per package and more than 2 Marking packages per consignment. © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 29: Use As Tracking Device Or Gateway In A Road/Rail/Sea Freight Transport

    More than 2 batteries (devices) per package: battery handling label required. • Marking ocean freight No marking required. containers Documentation No documentation required. Miscellaneous Personnel shall be trained commensurate with responsibilities. © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 30: Air Transport Pao/Cax

    The use of an active Connect S2 Gateway in an aircraft is generally not permitted. If you need a Connect S Gateway for use in aircraft, please contact sales.tnt@de.bosch.com for specific Connect S2 gateways approved for air transport tracking. © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 31: Disposal

    Bosch if Bosch is the owner of the hardware or if the hardware is still under warranty. In any case, as well as if Bosch is not the owner of the device or if the device is no longer under warranty, it must be ensured that the device, the accessories and the packaging are to be disposed of separately in an environmentally friendly manner;...
  • Page 32: Certifications And Regulatory Notes

    North Korea, Syria, Turkey and Ukraine. Federal Communications Commission (FCC) Notice FCC has issued an EQUIPMENT AUTHORIZATION to Robert Bosch Manufacturing Solutions GmbH – Bosch Connected Industry for Connect S and Connect L according to FCC rule parts 15 with the FCC ID: 2AOSY-CONNECT02 The manufacturer is not responsible for any changes or modifications not expressly approved by the party responsible for compliance.
  • Page 33: Intended Use

    Bosch product could cause personal injury or death. The same applies to any type of weapon or device or application that could potentially endanger people.
  • Page 34: Safety Notes

    In these cases, mounting the device with the mounting magnets is not permitted.  DO NOT attach the gateway to the outside of moving objects such as trucks, trailers, cars or other vehicles using the magnets. © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 35: Safety Instructions For Handling The Mounting Magnets

    Magnetic fields of improperly packaged magnets could influence airplane navigation devices. In the worst case it could lead to an accident.  Airfreight magnets only in packaging with sufficient magnetic shielding.  Please refer to the respective regulations. © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 36: Safety Instructions For Mounting With Solar Frame

    The supplied flange nuts have been specially selected for mounting the solar frame and must be used ONLY ONCE. If the Solar Frame must be dismounted, always use new flange nuts. Only use the flange nuts supplied.  Use them only once. No multiple use.  © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 37: Third-Party Licenses And Components

    THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 38 THE INTERNET ENGINEERING TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...
  • Page 39 Please submit your questions, comments and suggestions for improvement via our contact website Robert Bosch Manufacturing Solutions GmbH BCI - Bosch Connected Industry BCI/PAL Wernerstr. 51 70469 Stuttgart Germany Support.TnT@de.bosch.com Please insert the contact details accordingly © Robert Bosch Manufacturing Solutions GmbH Bosch Connected Industry...

Table of Contents