72
en | No Data Received Reports
13
No Data Received Reports
If a message is garbled (incorrect checksum or inconsistent message rounds) due to a noisy
telephone line or other difficulty, the receiver withholds the kiss-off tone. This causes the
control panel to send the same message again up to four times.
13.1
No Data Received
The D6600/D6100IPv6 generates one or more of the following events:
–
–
–
Figure 13.1: No Data Received Message
13.2
Data Error
Data Error is a function of PSTN. It is an error condition when the D6600/D6100IPv6 receives
partial data, appears on the LCD, and sends the error to a connected printer.
This occurs when telephone line noise causes data to be unrecognizable.
13.3
Wrong Data
Wrong Data is a function of the CPU where the PSTN software sends an invalid signal to the
CPU. It only sends output to the LCD and any connected printer.
2012.11 | 08 | 4998122704
Telephone line noise causes the data to be unrecognized.
A control panel sends the data in a format not recognized by the D6600/D6100IPv6.
A control panel transmitted nothing.
Installation and Operation Guide
Conettix Communications Receiver/
Gateway
Bosch Security Systems, Inc.