Conettix D6600/D6100Ipv6 Pre-Installation Requirements; Setting Up The Conettix D6600/D6100Ipv6 Over An Ethernet Network; Host Computer For Conettix D6600/D6100Ipv6 System Setup; Operation - Bosch Conettix D6600 Installation And Operation Manual

Communications receiver/gateway
Hide thumbs Also See for Conettix D6600:
Table of Contents

Advertisement

46
en | Network Communications
Callout ᅳ Description
6 ᅳ Local PC or SMS-capable cell phone for
configuration
7 ᅳ Antenna cable
8 ᅳ Magnetic base antenna
12.1

Conettix D6600/D6100IPv6 Pre-installation Requirements

Consider the following pre-installation requirements before attempting to install a Conettix
D6600/D6100IPv6 Network system. If you have any questions regarding these items, contact
the network administrator for the network with which you will interface, or a Bosch network
engineer.
Notice!
i
For UL Listed Fire Installations, shared on-premises communications equipment is required to
be UL Listed for Information Technology Equipment.
12.1.1

Setting Up the Conettix D6600/D6100IPv6 over an Ethernet Network

12.1.2

Host Computer for Conettix D6600/D6100IPv6 System Setup

12.2

Operation

12.2.1

Setting Up the Host Computer

Notice!
If the computer you plan to use for programming the D6600, the D6100IPv6, the D6680/
i
D6682, and the alarm panel network adapters is already a functioning workstation within the
network you are planning to utilize, refer to Network Failover Solution (D6600 Only), page 51.
2012.11 | 08 | 4998122704
The Ethernet network must use Ethernet cables.
The D6200 host computer must have a properly configured Ethernet network interface
card (NIC) installed.
The D6600 must be connected to the Ethernet network using a Bosch D6686/D6682/
D6680 Network Adapter or a D6100IPv6 must be connected to the Ethernet network.
The host computer uses the ARP and TELNET DOS commands to configure the D6680/
D6682, D6100i or D6100IPv6, D9133TTL-E or DX4020, or C900V2/C900TTL-E. The D6200
software can be used instead of the ARP and TELNET commands. Refer to the D6200
Software Operation and Installation Guide (P/N: 4998154991) and the appropriate network
device installation guide.
The host computer uses the D6200 to configure the D6686 or the D6100IPv6.
The host computer must have a properly configured Ethernet network interface card
(NIC) installed.
The host computer must have the appropriate Ethernet cable. Manually set the host
computer's IP address to an address that is acceptable to the particular class of the
network.
Installation and Operation Guide
Conettix Communications Receiver/
Callout ᅳ Description
14 ᅳ PSTN connection
15 ᅳ Conettix D6600 or Conettix
D6100iPv6 Receiver
Bosch Security Systems, Inc.
Gateway

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Conettix d6100ipv6

Table of Contents