If using Network Automation, it is recommended that this be setup done using the D6200 af-
ter it can communicate with the D6100IPv6.
6.
7.
Notice!
When entering an IP address through the keypad of the D6100IPv6, press the UP button for a
i
"." in a IPv4 address and the DOWN button for a ":" in an IPv6. For example enter IP address
192.168.1.3 as: [1][9][2][∆][1][6][8][∆][1][∆][3][ENTER].
8.
9.
12.5

D6100i Configuration Setup Instructions

The instructions in this section are for legacy D6100i modules.
12.5.1

Identifying the MAC Hardware Address

You must program the IP address of the module. The first step is to determine the MAC, or
hardware, address of the module. This address is hard-coded into the module during its
manufacture and cannot be changed. This address is 6 bytes (12 digits) long.
Figure 12.7: MAC Address Label Example
Notice!
i
The MAC address label is located on the rear of the module below the Ethernet port.
Record this number for future reference.
12.5.2

Obtaining an IP Address

Provide the module's MAC address to the site's network administrator, who then assigns an IP
address for the D6100IPv6.
2012.11 | 08 | 4998122704
Press Down to view 6.2.5 Network Adapter Enabled, and then verify it is a value of 2 and
press Enter. If the value is not 2, press Enter>[2]>Enter.
If the D6100IPv6 has encryption enabled, press Down until viewing 6.2.6 Network
Encryption Enabled and set it to 1 using the same method as above.
Press Cancel and press Down until viewing 6.4 D6200 Network Connections, and then
press Enter.
Press Enter to enter the IP address into 6.4.1 or Login Password into 6.4.6 of the host
computer that is running the D6200 Software.
Verify that 6.4.5 Network Programming Enable is a 1. If the value is not 1, press Enter
[1] Enter.
Press Cancel repeatedly to return to the idle stage (the time and date show on the LCD).