Using Telnet To Finish The Configuration - Bosch Conettix D6600 Installation And Operation Manual

Communications receiver/gateway
Hide thumbs Also See for Conettix D6600:
Table of Contents

Advertisement

66
en | Network Communications
The network uses this table to identify devices and to route signals. The number of devices
and other types (static and dynamic, as shown in the example) depends on the network and
the number and type of devices with which this COMPUTER communicates. Identify the MAC
address of the device you are installing and verify that it now has an IP address linked to it.
12.5.4

Using Telnet to Finish the Configuration

Notice!
i
To use Telnet, you must log in as a user with Administrative privileges.
In Windows Vista, Telnet is disabled by default. In order to use Telnet, you must enable it:
1.
2.
3.
4.
Notice!
i
The MAC address, IP address, gateway IP address, and port number in this procedure are ex-
amples and are not the same as those for your C900V2.
Notice!
By default, Windows Vista does not install the Telnet client. The Telnet client is for text-based
communication with remote systems.
To install the Telnet client on a PC running Windows Vista:
1. Click Start→Control Panel.
i
2. Select Programs and Features.
3. Select Turn Windows Features on or off.
4. Select the Telnet Client option.
5. Click OK.
A dialog box opens to confirm installation. The telenet command is now available.
5.
6.
7.
8.
2012.11 | 08 | 4998122704
Click Start>Control Panel>Programs.
Click Turn Windows features on or off. If you are prompted for an administrator password
or confirmation, type the password or provide confirmation.
In the Windows Features dialog box, select the Telnet Client check box.
Click OK. The installation might take several minutes
Select Start → Run. The Run dialog box appears.
In the Run dialog box, type telnet and click OK. The Telnet window appears.
Type open <IP ADDRESS> 1 and press Enter (where <IP ADDRESS> is the IP address of
the D6100i). Type a space after open and after the IP address. For example:
open 172.17.10.70 1. The connection fails the first time. This is normal.
Repeat Step 3 using 9999 as the port number.
Installation and Operation Guide
Conettix Communications Receiver/
Gateway
Bosch Security Systems, Inc.