Busy Seconds (Line Busy) Reports - Bosch Conettix D6600 Installation And Operation Manual

Communications receiver/gateway
Hide thumbs Also See for Conettix D6600:
Table of Contents

Advertisement

38
en | D6600/D6100IPv6 Operation
Clear Pending Events (Function 4)
Use this option to clear all pending events.
Running the Clear Pending Events function:
1.
2.
3.
LCD/LED Availability Test (Function 5)
Use this option to clear all pending events.
Running the LCD/LED Availability Test function:
1.
2.
The LCD changes all segments to black for 2 sec so that you can check for nonfunctioning LCD
segments. All D6641 Line Cards turn the line LEDs on red for 2 sec and then green for 2 sec.
The Power and System trouble LEDs turn on for 2 sec, then off. After the test completes, the
system restores the LEDs to their previous state.
11.5

Busy Seconds (Line Busy) Reports

The D6600/D6100IPv6 monitors and reports when a call group of receiver lines cannot receive
signals. The receiver cannot process signals if its incoming telephone lines are in trouble, if
other communicators have the line tied up, or if the line card is inoperative. The receiver
interprets telephone lines that are not in trouble and taking calls as busy time. Telephone lines
that are in trouble are not included in the busy time calculation.
The amount of busy time accumulated during a 10 min period is the basis for a Busy Seconds
Reports. The 10 min busy period begins when all lines in a call group become busy, or when a
non-programmed single line for a call group becomes busy. The D6600/D6100IPv6 totals the
accumulated busy time and prints the Busy Seconds Report after the 10 min period ends.
After at least 60 sec (10%) of busy time, the receiver generates a report. The D6600/
D6100IPv6 reports up to 100% busy time.
Program the Busy Seconds Reports option to No if Busy Seconds Reports are not wanted for
all lines. Setting the Line Sniff option to 2 disables reports for individual lines.
Notice!
i
Enable Seconds Reports for UL Listed central stations.
UL inspectors might investigate the amount of time the digital receiver lines cannot receive
signals. Ensure that lines are available to process emergency signals on a timely basis.
Excessive Line Busy Reports can indicate it is necessary to install additional lines in rotary
with your primary receiver lines.
Assign each line to a call group. For the group to start accumulating busy time, all lines in the
call group must be online, in trouble, or without an operating line card.
2012.11 | 08 | 4998122704
Press the Function key. Enter your password and press the Enter key to go to the
Welcome Manager.
Press [4] and Enter.
Press [0] to cancel the function and not delete all pending events, or press [1] to clear all
pending events.
Press the Function key. Enter your password and press the Enter key to go to the
Welcome Manager.
Press [6] and Enter.
Installation and Operation Guide
Conettix Communications Receiver/
Gateway
Bosch Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Conettix d6100ipv6

Table of Contents