Conettix D6600/D6100i | Installation and Operation Guide | 5.0 Power Supply Modules (D6600 Only)
4.2.3

Card Removal and Replacement

Remove power to the D6600 before
removing, replacing, or installing the
CPU card (D6610) or CPU terminator
card (D6615).
Removing the CPU Card
1. Remove power to the receiver (refer to Section
7.3 Removing Power to the Receiver on
page 11).
2. Carefully grasp the plastic grip on the CPU card.
Slide it 2 in. to 3 in. (50 mm to 75 mm) out of the
enclosure.
3. Unplug the 50-pin ribbon cable connecting the
user interface card to the CPU card. Be careful
not to bend the board when disconnecting this
cable. Grasp the plastic plug connected to the
CPU board at the end of the cable and gently pull
it away from the circuit board.
4. Pull the CPU card straight out of the card guide.
Replacing the CPU Card
1. Remove power to the receiver (refer to Section
7.3 Removing Power to the Receiver on
page 11).
2. Remove the defective CPU card from the
enclosure.
3. Align the top and bottom of the CPU card with the
card guides. Slide the card into the enclosure,
leaving 2 to 3 in. (50 mm to 75 mm) out to
connect the ribbon cable.
4. Connect the ribbon cable to the CPU card. Orient
the cable so the red stripe is up, and slide the
card the remaining distance into the enclosure.
5. Restore power to the receiver.
5.0 Power Supply Modules
(D6600 Only)
The AC/DC (D6630) and DC/DC
(D6631) Power Supply Modules are not
field serviceable.
Contact the Bosch Security Systems,
Inc. National Repair Center at (800)
289-0096 for repair or replacement.

6.0 Printer Specifications

Refer to the appropriate Installation
Supplement included with your product
for the specifics of your particular

installation.

10
Parallel printer connection: Use the DB25 port on
the back of the D6600/D6100i rear panel to connect
to a standard parallel text printer.
Models: SAFECOM SC9002 (Star 300) requires
82.6 mm. (3.25 in) wide paper.
7.0 Installation
Refer to the appropriate Installation
Supplement included with your product
for the specifics of your particular
installation.
7.1

Installation Check List

1. Check each receiver card to see that it is correctly
positioned in the card guides at the top and
bottom of the enclosure. Also confirm that
connections did not loosen during shipment
(D6600 only).
2. Ensure that the earth ground is connected and
grounded through the AC inlet.
3. If you are installing additional line cards, install
the terminator cards now (D6600 only).
4. After installing additional line terminator cards,
install the line cards (refer to Section 4.1.2 Card
Installation on page 8).
5. You might also want to install the line terminator
card(s) from your spares package(s). If there is a
malfunction, you can quickly switch over to the
replacement card (refer to Section 4.1.2 Card
Installation on page 8).
You can install spare line terminator
cards. Do not install spare line cards.
6. Connect four or six conductor telephone cord(s)
to the RJ11C jack(s) of the desired telephone
line(s). Plug the other end of the modular
telephone cord(s) into the telephone jack on the
appropriate line terminator card(s).
7. Connect the supplied AC transformer wiring leads
to the AC terminals on the rear of the D6100i.
8. Plug the AC cord (D6600 only) into a correctly
wired 120 VAC, 60 Hz or 220 VAC, 50 Hz outlet
(standard AC outlet).
Maintain a 6.5 mm (0.25 in.) gap, or
greater, between power limited and non-
power limited circuit wiring.
9. Plug the AC transformer into the correctly wired
wall receptacle that matches the voltage of the
transformer.
Ensure that a switch does not control
the outlet.
Bosch Security Systems, Inc. | 6/09 | 4998122704-06