Figure 104: Installing An Mpc - Juniper MX240 Hardware Manual

3d universal edge router
Hide thumbs Also See for MX240:
Table of Contents

Advertisement

MX240 3D Universal Edge Router Hardware Guide
Related
Documentation
196
CAUTION:
Avoid bending fiber-optic cable beyond its minimum bend
radius. An arc smaller than a few inches in diameter can damage the cable
and cause problems that are difficult to diagnose.
Use one of the following methods to bring the MPC online:
13.
Press and hold the corresponding MPC online button on the craft interface until the
green
LED next to the button lights steadily, in about 5 seconds.
OK/FAIL
Issue the following CLI command:
user@host>request chassis fpc slot slot-number online
For more information about the command, see the Junos OS Operational Mode
Commands.
CAUTION:
After the
before removing the MPC again, removing an MPC from a different slot,
or inserting an MPC in a different slot.
You can also verify correct MPC and MIC functioning by issuing the
show chassis fpc pic-status
page 126
and
"Maintaining MX240 MICs" on page

Figure 104: Installing an MPC

MPC
SC B
SC B
MX240 Modular Port Concentrator (MPC) Description on page 20
Maintaining MX240 MPCs on page 126
Replacing an MX240 MIC on page 197
MX240 MPC Serial Number Label on page 297
Preventing Electrostatic Discharge Damage to an MX240 Router on page 226
LED lights steadily, wait at least 30 seconds
OK/FAIL
commands described in
"Maintaining MX240 MPCs" on
127.
show chassis fpc
Copyright © 2013, Juniper Networks, Inc.
and

Advertisement

Table of Contents
loading

Table of Contents