11.0 The Master Keypad (Text Keypad Only)

11.1

General Information

Your system can include a Master Keypad. A Master Keypad is a text keypad programmed to provide access to
all areas assigned to you, not just the area in which the Master Keypad is located. This is different from a standard
keypad because standard keypads provide access only to the single area in which they are located. Commands
entered at the Master Keypad affect all the areas to which you have access. If this is not desirable, the Master
Keypad can control each area individually using Single Partition Mode. Single Partition Mode allows you to
control any or all of the areas to which you have access on an individual (one by one) basis (refer to Section 11.3
Single Partition Mode).
To use the Master Keypad, your PIN must be assigned to the area in which the Master Keypad is
located.
11.2

Master Keypad Displays

Master keypad displays differ slightly from standard keypads. The Master Keypad display scrolls the status of each
area, followed by the area number. For example, if all areas are armed, the Master Keypad scrolls through the
following displays:
Armed
Armed
area 1
area 2
If only areas 1, 2, 3, 4, 6, and 8 are armed, the Master Keypad scrolls through the following displays:
Armed
Armed
area 1
area 2
Areas that are not ready display as "Not Ready."
Table 30 helps you understand what each LED function of the Master keypad represents.
Table 30: Master Keypad LEDs
LED
Off
Armed
All areas are disarmed.
(red)
Status
Not ready to arm (if the Armed LED
(green)
is on, all areas are armed).
Power
The control panel lost all power; no
(green)
AC or battery.
Fire
There are no fire alarms.
(red)
Bosch Security Systems | 6/05 | 4998154961B
The Master Keypad (Text Keypad Only)
Armed
Armed
area 3
area 4
Armed
Armed
area 3
area 4
Flashing
One or more areas are armed, or
an alarm occurred.
One or more zones are
bypassed.
Control panel problems exist.
Refer to Section 9.0 Error
Displays on page 25.
A fire zone is in alarm.
Armed
Armed
area 5
area 6
Ready to
Armed
Arm area 5
area 6
On
All areas are armed, and no alarms
occurred.
All areas are ready to arm.
Normal Operation. The control panel is
running on AC power with no problem.
A fire trouble condition exists.
EN | 31
Armed
Armed
area 7
area 8
Ready to
Armed
Arm area 7
area 8