17. 20/30 Loop Phase Lock Adjustments
3-l 54 Adjustments
\
TOP VIEW
Figure 3-79. Location of PLL2 Adjustments
6. Adjust AlOA5R2 150 MHz adjustment for a DVM indication of
150 MHz adjustment.
7. Adjust AlOA8R9 .3 MHz adjustment for a frequency counter
indication of 0.300 MHz f 0.001 MHz. Refer to Figure 3-79 for the
location of AlOA8R9 .3 MHz adjustment.
8. On the RF Section, key in
The CRT annotation will round off to 8.59 MHz, but the RF Section is
actually set to a start frequency of 8.599 MHz.
9. Adjust AlOA5R4 100 MHz adjustment for a DVM indication
of + 15.0 f 0.5 Vdc. Refer to Figure 3-79 for the location of
10. Adjust AlOA8R41 .2 MHz adjustment for a frequency counter
indication of 0.200 f 0.001 MHz. Refer to Figure 3-79 for the
location of AlOA8R41 .2 MHz adjustment.
D I S C R I M I N A T O R
R 4
I
[
8.599 MHz, SWEEP
START