RIGOL
external memory in a single ".csv" file. You can specify the file name and the
saving directory and save the corresponding parameter file (.txt) under the
same directory using the same file name the function of this parameter file is
the same to the Parameters. The recall of CVS and parameter files is not
supported.
After selecting this type:
Press DataSrc to select "Screen" or "Memory". After selecting "Memory", press
Channel to select the desired channel (note that only channels currently
enabled can be selected).
Press Param to enable or disable the parameter save function.
6. Parameters
Save the waveform parameters displayed on the screen in external memory in
".txt" format. The parameters include the current system informations (such as
model, firmware version and software version and so on) and the current
relative settings information (such as vertical system, horizontal system and
normal trigger system).
13-4
Chapter 13 Store and Recall
DS1000Z User's Guide