TimeOut: set the minimum time that the clock (SCL) signal must be idle before
the oscilloscope starts to search for the data (SDA) on which to trigger. Press
TimeOut to set the timeout value and the range is from 100 ns to 1 s. Note that,
at this point, CS is invalid (not displayed).
Data Line Setting:
Set the instrument to trigger when the specified bit and length of data is transmitted
in the SDA.
Press Data Bits to set the number of bits of the serial data character string. It
can be set to any integer between 4 and 32.
Press CurrentBit to set the number of the data bit and the range is from 0 to
(value sepecified in Data Bits – 1).
Press Data to set the value of the current bit to H, L or X.
Press AllBits to set all the data bits to the value specified in Data.
Clock Edge:
Press Clock Edge to select the desired clock edge.
: sample the SDA data on the rising edge of the clock.
: sample the SDA data on the falling edge of the clock.
Trigger Mode:
Press Sweep to select the
normal or single. The corresponding status light of the current trigger mode turns on.
Trigger Setting:
Press Setting to set the trigger parameter (noise rejection) under this trigger type.
Trigger Level:
Use TRIGGER
description of
"Trigger
5-40
Trigger Mode
LEVEL to modify the level. For details, please refer to the
Level" on page 5-9.
Chapter 5 To Trigger the Oscilloscope
(page 5-3) under this trigger type as auto,
DS1000Z User's Guide