To do...
Enable information
output to the log buffer
Configure the output
rules of system
information
Set the format of time
stamp in the output
information
Setting to Output System Information to the SNMP NMS
Follow these steps to set to output system information to the SNMP NMS:
To do...
Enter system view
Enable the information
center
Enable information
output to the SNMP NMS
Configure the output
rules of system
information
Set the format of time
stamp in the output
information
To send information to a remote SNMP NMS properly, related configurations are required on both the
switch and the SNMP NMS. For the detailed configuration, refer to the SNMP-RMON part.
Use the command...
info-center logbuffer [ channel
{ channel-number |
channel-name } | size buffersize ]*
info-center source { modu-name |
default } channel
{ channel-number |
channel-name } [ { log | trap |
debug } { level severity | state
state } ]*
info-center timestamp { log | trap
| debugging } { boot | date |
none }
Use the command...
system-view
info-center enable
info-center snmp channel
{ channel-number |
channel-name }
info-center source { modu-name |
default } channel
{ channel-number |
channel-name } [ { log | trap |
debug } { level severity | state
state } ]*
info-center timestamp { log | trap
| debugging } { boot | date |
none }
1-13
Remarks
Optional
By default, the switch uses
information channel 4 to output log
information to the log buffer, which
can holds up to 512 items by
default.
Optional
Refer to
Table 1-4
for the default
output rules of system information.
Optional
By default, the time stamp format
of the output log information is
date.
Remarks
—
Optional
Enabled by default.
Optional
By default, the switch outputs trap
information to SNMP through
channel 5.
Optional
Refer to
Table 1-4
for the default
output rules of system information.
Optional
By default, the time stamp format
of the information output to the
SNMP NMS is date.