Setting to output system information to a monitor terminal
Follow these steps to set to output system information to a monitor terminal:
To do...
Enter system view
Enable the information
center
Enable system
information output to
Telnet terminal or
dumb terminal
Configure the output
rules of system
information
Set the format of time
stamp in the output
information
When there are multiple Telnet users or dumb terminal users, they share some configuration
parameters including module filter, language and severity level threshold. In this case, change to
any such parameter made by one user will also be reflected on all other user terminals.
To view debugging information of specific modules, you need to set the information type as debug
when setting the system information output rules, and enable debugging for corresponding
modules through the debugging command.
Enabling system information display on a monitor terminal
After setting to output system information to a monitor terminal, you need to enable the associated
display function in order to display the output information on the monitor terminal.
Follow these steps to enable the display of system information on a monitor terminal:
To do...
Enable the debugging/log/trap
information terminal display function
Enable debugging information
terminal display function
Enable log information terminal
display function
Use the command...
system-view
info-center enable
info-center monitor channel
{ channel-number | channel-name }
info-center source { modu-name |
default } channel { channel-number |
channel-name } [ { log | trap | debug }
{ level severity | state state } ]*
info-center timestamp { log | trap |
debugging } { boot | date | none }
Use the command...
terminal monitor
terminal debugging
terminal logging
1-10
Remarks
Optional
Enabled by default.
Optional
By default, a switch outputs
log/debugging/trap information to
a user terminal through
information channel 1.
Optional
Refer to
Table 1-4
for the default
output rules of system
information.
Optional
By default, the time stamp format
of the log and trap output
information is date, and that of
the debugging output information
is boot.
Remarks
Optional
Enabled by default
Optional
Disabled by default
Optional
Enabled by default